PHILADELPHIA, PA —
OSHA Inspection: DELTABJDS, INC.
Federal Agency inspection · Safety discipline
At a glance
On , OSHA opened a federal Agency safety inspection of DELTABJDS, INC. in 6523 LANSDOWNE AVE, PHILADELPHIA, PA 19151 (NAICS 236220). OSHA activity number 347468555.
Where did this inspection happen?
- Establishment
- DELTABJDS, INC.
- Site address
- 6523 LANSDOWNE AVE
- City
- PHILADELPHIA
- State
- PA
- ZIP
- 19151
- Mailing
- 1345 INDUSTRIAL BOULEVARD, SOUTHAMPTON, PA 18966
What kind of inspection was it?
- Inspection type
- Federal Agency (M)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236220
- Employees
- 4
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.28 A
- Issued
- Abate by
- Penalty
- Initial $11292.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1926.28(a): The employer did not require the wearing of appropriate personal protective equipment in all operations where there is an exposure to hazardous conditions: a) Jobsite located at or near 6523 Lansdowne Ave, Philadelphia, Pennsylvania- On or about May 8, 2024, the employer did not require the employee to wear insulated gloves while working with the Midwest Fasteners, Inc. Talon Stud Welder with a voltage ranging from 35 volts to 175 DC volts, thereby exposing employees to electrical hazards.
Recent events (3)
- — F (S) $0
- — C (S) $11292
- — Z (S) $11292
1926.351 B04
- Issued
- Penalty
- Initial $11292.00 · Current $11292.00
General-duty citation text
29 CFR 1926.351(b)(4): Welding cable(s) in use were in need of repair: a) Jobsite located at or near 6523 Lansdowne Ave, Philadelphia, Pennsylvania- On or about May 8, 2024, the employer did not ensure welding cables that were in need of repair were not used by employees and removed from service. Employees used welding cables with numerous visible defects including cuts in the insulation and exposed wires, thereby exposing employees to electrical hazards.
Recent events (3)
- — F (O) $11292
- — C (S) $11292
- — Z (S) $11292
1926.403 B01
- Issued
- Penalty
- Initial $16131.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1926.403(b)(1): Employer did not ensure that electrical equipment is free from recognized hazards that are likely to cause death or serious physical harm to employees: a) Jobsite located at or near 6523 Lansdowne Ave, Philadelphia, Pennsylvania- On or about May 8, 2024, the employer did not ensure the equipment is free from recognized hazards that are likely to cause death or serious physical harm to employees. The employer did not examine the stud welder, Midwest Fasteners, Inc., Model: Talon, Serial Number: TAL-1217-235 prior to use and allowed employees to use with defects such as, but not limited cables of the welder had numerous cuts in multiple areas of exposed wires and a screw on the weld gun was missing, thereby exposing employees to electrical hazards. b) Jobsite located at or near 6523 Lansdowne Ave, Philadelphia, Pennsylvania- On or about May 8, 2024, the employer did not ensure the equipment is free from recognized hazards that are likely to cause death or serious physical harm to employees. The employer did not examine a AWG 14-gauge extension cable prior to use and allowed employees to use with defective ground and exposed insulation, thereby exposing employees to electrical hazards.
Recent events (3)
- — F (S) $0
- — C (S) $16131
- — Z (S) $16131
1926.416 E01
- Issued
- Penalty
- Initial $11292.00 · Current $11292.00
General-duty citation text
29 CFR 1926.416(e)(1): Worn or frayed electric cords or cables were used: a) Jobsite located at or near 6523 Lansdowne Ave, Philadelphia, Pennsylvania- On or about May 8, 2024, the employer did not ensure worn, or damaged flexible cord sets were removed from service. Employees used flexible cord sets with external defects including but not limited to damaged wire insulation and broken ground connection, thereby exposing employees to electrical hazards.
Recent events (3)
- — F (S) $11292
- — C (S) $11292
- — Z (S) $11292
1904.40 A
- Issued
- Penalty
- Initial $1613.00 · Current $1613.00
General-duty citation text
29 CFR 1904.40(a): The employer did not provide an authorized government representative the records within the four business hours. a) DeltaBJDS, Inc., located at 1345 Industrial Blvd, Southampton, PA 18966- On or about May 8, 2024, the employer failed to provide copies of OSHA Forms 300 and 300-A or their equivalents within four (4) business hours, which were requested for calendar years 2021, 2022 and 2023.
Recent events (3)
- — F (O) $1613
- — C (O) $1613
- — Z (O) $1613
More inspections in this industry (NAICS 236220)
IRVINE, CA—2026-07-13
SNEARY CONSTRUCTION, INC.
IRVINE, CA—2026-07-13
KUKBO DESIGN USA LLC
SIOUX FALLS, SD—2026-07-13
REM CONSTRUCTION SERVICES, LLC
INDIAN ROCKS BEACH, FL—2026-07-10
UNKNOWN CONTRACTOR
SIOUX FALLS, SD—2026-07-10
HENRY CARLSON COMPANY
More inspections in PA
MILTON, PA—2026-07-10
HOMETOWN FOODS CHEF BOYARDEE CO.
SUNBURY, PA—2026-07-10
DEMPSEY UNIFORM & LINEN SUPPLY, INC
LANDISVILLE, PA—2026-07-10
FAIRVIEW DEMOLITION LLC
YORK, PA—2026-07-10
AMERICAN SPECIALTY SYSTEMS INC.
WILLIAMSPORT, PA—2026-07-10
INTERNATIONAL PAINT PROS
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347468555.