Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: READY WINDOW SALES & SERVICE, CORP.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of READY WINDOW SALES & SERVICE, CORP. in 12537 DISTRIBUTION BLVD, LAKE PLACID, FL 33852 (NAICS 493110). OSHA activity number 347494791.

Watch Ready Window Sales & Service, Corp. — free Get an email when a new federal OSHA severe-injury report for Ready Window Sales & Service, Corp. is published. One employer, no account, unsubscribe in one click.
Site address
12537 DISTRIBUTION BLVD
City
LAKE PLACID
State
FL
ZIP
33852
Mailing
5901 NW 36 STREET, MIAMI, FL 33146
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
493110
Employees
8
Ownership type
A

4 citations on file for this inspection.

1910.22 A01

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $6453.00 · Current $6453.00
29 CFR  1910.22(a)(1):29 CFR 1910.22(a)(1): The employer did not ensure that all places of employment, passageways, storerooms, service rooms, and walking-working surfaces are kept in a clean, orderly, and sanitary condition:  (a) In the racking area:  On or about 5/21/2024, the employer exposed employees to trip/fall hazards, in that, the floor in front of the storage racks had aluminum beams scattered all around.
Recent events (1)
  • — Z (S) $6453

1910.305 G01 IV A

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $6453.00 · Current $6453.00
29 CFR  1910.305(g)(1)(iv)(A):Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:  (a) At the break area; On or about 5/21/2024, flexible cords were used as a substitute for the fixed wiring for the microwave, toaster, and refrigerator.
Recent events (1)
  • — Z (S) $6453

1910.334 A01

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.334(a)(1): Flexible electric cords were fastened with staples or otherwise hung in such a fashion as could damage the outer jacket or insulation:  (a) At the break area; On or about 5/21/2024, the relocatable power tap was hung over an approximately 3 inch wide metal bracket in such a way that could damage the outer jacket.
Recent events (1)
  • — Z (S) $0

1910.178 L04 III

Other-than-serious 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.178(l)(4)(iii): An evaluation of each powered industrial truck operator's performance was not being conducted at least once every three years:  (a) At the warehouse; On or about 5/21/2024, the employer failed to evaluate powered industrial truck operators at least every three years.
Recent events (1)
  • — Z (O) $0

View READY WINDOW SALES & SERVICE, CORP.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347494791.