1,224,460Inspections Most recent open 2026-07-13 Last loaded 2026-07-16
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Inspection: SELECTIVE COATINGS & INKS, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of SELECTIVE COATINGS & INKS, INC. in 5008 INDUSTRIAL ROAD, WALL TOWNSHIP, NJ 07727 (NAICS 325910). OSHA activity number 347529612.

Watch Selective Coatings & Inks, INC. — free Get an email when a new federal OSHA severe-injury report for Selective Coatings & Inks, INC. is published. One employer, no account, unsubscribe in one click.
Site address
5008 INDUSTRIAL ROAD
City
WALL TOWNSHIP
State
NJ
ZIP
07727
Mailing
5008 INDUSTRIAL ROAD, WALL TOWNSHIP, NJ 07727
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Last modified
Data loaded
NAICS code
325910
Employees
7
Ownership type
A

3 citations on file for this inspection.

1910.106 E06 I

Serious Gravity 10 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $6452.00 · Current $4166.00 Reduced
29 CFR  1910.106(e)(6)(i):Adequate precautions were not taken to prevent the ignition of flammable vapors:  a) Selective Coatings & Inks, Inc. - Front room/Dispensing area:  A grounding wire was not used where employees transferred flammable materials from full to empty drums.  On 06/05/2024 an employee was transferring  dimethyl carbonate, a flammable chemical,  into an empty drum without a grounding wire and the drum exploded.
Recent events (2)
  • — I (S) $4166
  • — Z (S) $6452

1910.106 H04 IV A

Serious Gravity 10 1 instance 3 exposed
Issued
Penalty
Initial $6452.00 · Current $4167.00 Reduced
29 CFR  1910.106(h)(4)(iv)(a):  Equipment was not designed and arranged to prevent the unintentional escape of liquids and vapors and to minimize the quantity escaping in the event of accidental release.  a) Selective Coatings & Inks, Inc. - Front room/Dispensing area:  The Flux Pump - Model # F416/1 - S/N 41614324, used to transfer flammable liquids from one drum to another, was not designed or configured to prevent unintentional escape of liquids and vapors. On 06/05/2024 the pump continued to operate after a drum exploded resulting in the release of flammable liquid into the work area.
Recent events (2)
  • — I (S) $4167
  • — Z (S) $6452

1910.132 A

Serious Gravity 10 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $6452.00 · Current $4167.00 Reduced
29 CFR  1910.132(a):  Protective equipment was not used when necessary, whenever hazards capable of causing injury and impairment were encountered:  a) Selective Coatings & Inks, Inc. - Front room/Dispensing area:  The employer did not enforce the use of flame-resistant uniforms, including long-sleeve shirts and long pants, to protect employees from burns when transferring and handling flammable chemicals.  On 06/05/2024 an employee sustained second degree burns after the polyester clothing he was wearing caught fire due to an explosion.
Recent events (2)
  • — I (S) $4167
  • — Z (S) $6452

View SELECTIVE COATINGS & INKS, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347529612.