OSHA Inspection: EXO GROUP, LLC

Federal Agency inspection · Safety discipline

On , OSHA opened a federal Agency safety inspection of EXO GROUP, LLC in WALTER R. BISHOP WATER TREATMENT PLANT, PRENTISS, MS 39474 (NAICS 321114). OSHA activity number 347673337.

Watch EXO Group, LLC — free Get an email when a new federal OSHA severe-injury report for EXO Group, LLC is published. One employer, no account, unsubscribe in one click.
Establishment
EXO GROUP, LLC
Site address
WALTER R. BISHOP WATER TREATMENT PLANT
City
PRENTISS
State
MS
ZIP
39474
Mailing
1735 HUGHES LANDING BLVD. SUITE FLOOR 3, THE WOODLANDS, TX 77381
Inspection type
Federal Agency (M)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
321114
Employees
2
Ownership type
A

2 citations on file for this inspection.

1910.269 A02 I A

Deleted Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $14895.00 · Current $0.00 Reduced
29 CFR  1910.269(a)(2)(i)(A): Each employee was not trained in, and familiar with, the safety-related work practices, safety procedures, and other safety requirements in this section that pertain to his or her job assignments.  Jobsite - On or about August 6, 2024 employees inspecting guy wires were not provided specific training on identifying energized equipment, exposing employees to electrical hazards.
Recent events (3)
  • — F (S) $0
  • — C (S) $14895
  • — Z (S) $14895

1910.269 L08 IV

Deleted Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $16550.00 · Current $0.00 Reduced
29 CFR  1910.269(l)(8)(iv): The employer did not ensure that the outer layer of clothing worn by an employee, except for clothing not required to be arc rated under paragraphs (l)(8)(v)(A) through (l)(8)(v)(E) of this section, is flame resistant under any of the following conditions:   Jobsite - On or about August 6, 2024 employees inspecting guy wires were required to wear clothing such as but not limited to reflective vest and gloves that were not rated as flame resistant , exposing employees to electrical hazards.