WESTON, WI —
OSHA Inspection: HOME GUARD ROOFING LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of HOME GUARD ROOFING LLC in 3506 WALLEYE DRIVE, WESTON, WI 54476 (NAICS 238160). OSHA activity number 347683625.
Where did this inspection happen?
- Establishment
- HOME GUARD ROOFING LLC
- Site address
- 3506 WALLEYE DRIVE
- City
- WESTON
- State
- WI
- ZIP
- 54476
- Mailing
- 616 BUFFALO STREET, MANITOWOC, WI 54220
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 3
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.501 B13
- Issued
- Penalty
- Initial $4839.00 · Current $2242.00 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): "Residential construction." Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. Exception: When the employer can demonstrate that it is infeasible or creates a greater hazard to use these systems, the employer shall develop and implement a fall protection plan which meets the requirements of paragraph (k) of 1926.502. Note: There is a presumption that it is feasible and will not create a greater hazard to implement at least one of the above-listed fall protection systems. Accordingly, the employer has the burden of establishing that it is appropriate to implement a fall protection plan which complies with 1926.502(k) for a particular workplace situation, in lieu of implementing any of those systems. On or about August 13, 2024, at an establishment located at 3506 Walleye Drive in Weston, Wisconsin, employees of Home Guard Roofing LLC were performing residential roofing activities with no form of conventional fall protection while exposed to fall hazards of over 9 feet.
Recent events (2)
- — I (S) $2242
- — Z (S) $4839
1926.1053 B05 I
- Issued
- Penalty
- Initial $4148.00 · Current $2242.00 Reduced
General-duty citation text
29 CFR 1926.1053(b)(5)(i): Non-self-supporting ladders shall be used at an angle such that the horizontal distance from the top support to the foot of the ladder is approximately one-quarter of the working length of the ladder (the distance along the ladder between the foot and the top support). On or about August 13, 2024, at an establishment located at 3506 Walleye Drive in Weston, Wisconsin, employees of Home Guard Roofing LLC were observed utilizing a ladder that was not utilized at an approximate one-quarter the working length being exposed to fall hazards of 9.7 feet.
Recent events (2)
- — I (S) $2242
- — Z (S) $4148
More inspections in this industry (NAICS 238160)
SIOUX FALLS, SD—2026-07-13
H & R ROOFING OF SOUTH DAKOTA, INC.
HENDERSON, NV—2026-07-13
INTEGRITY ROOFING LLC
CORTLANDT MANOR, NY—2026-07-13
LG BUILDERS INC.
CAMDEN, OH—2026-07-13
ALBERTO MORALES
BLOOMINGTON, IL—2026-07-13
UNKNOWN CONTRACTOR
More inspections in WI
MUSCODA, WI—2026-07-10
SCOT INDUSTRIES, INC
FRANKLIN, WI—2026-07-10
EDGE BROADBAND SOLUTIONS LLC
APPLETON, WI—2026-07-10
LAWRENCE UNIVERSITY OF WISCONSIN
KIMBERLY, WI—2026-07-10
ENRIQUE RESENDIC
SLINGER, WI—2026-07-10
DYLAN MATTHEW SHELLEY LLC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347683625.