Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: TOPTIER ROOFING LLC

Special Programs inspection · Safety discipline

On , OSHA opened a special Programs safety inspection of TOPTIER ROOFING LLC in 1119 EUCLID AVE, SYRACUSE, NY 13210 (NAICS 238160). OSHA activity number 347708000.

Watch Toptier Roofing LLC — free Get an email when a new federal OSHA severe-injury report for Toptier Roofing LLC is published. One employer, no account, unsubscribe in one click.
Establishment
TOPTIER ROOFING LLC
Site address
1119 EUCLID AVE
City
SYRACUSE
State
NY
ZIP
13210
Mailing
113 KIMBER AVENUE, SYRACUSE, NY 13207
Inspection type
Special Programs (K)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
11
Ownership type
A

4 citations on file for this inspection.

1926.100 A

Serious Gravity 5 1 instance 4 exposed
Issued
Penalty
Initial $3318.00 · Current $1515.00 Reduced
29 CFR  1926.100(a):Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets:  a)  On or about 08/08/2024, on the site located at 1119 Euclid Ave, Syracuse, NY : Employees performing groundwork operations were not protected by a protective helmet exposing employees to struck by injuries.
Recent events (2)
  • — I (S) $1515
  • — Z (S) $3318

1926.416 A01

Serious Gravity 5 1 instance 3 exposed
Issued
Penalty
Initial $4149.00 · Current $1895.00 Reduced
29 CFR 1926.416(a)(1): The employer did not prevent employee(s) from working in proximity to an electric power circuit that the employee could contact during the course of work and the employee(s) were not protected against electric shock by de-energizing the circuit and grounding it or by guarding it effectively by insulation or other means:  a) On or about 08/08/2024, at the site located at 1119 Euclid Ave, Syracuse, NY 13212: Workers were not protected from electrical shock when using multiple tools, including but not limited to pneumatic nail guns, hammers and scrapers approximatley 1-2 feet from the incoming energized electrical service.
Recent events (2)
  • — I (S) $1895
  • — Z (S) $4149

1926.501 B13

Serious Gravity 5 1 instance 7 exposed
Issued
Penalty
Initial $4978.00 · Current $2275.00 Reduced
29 CFR  1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):    a) On or about 08/08/2024, on the site located at 1119 Euclid Ave, Syracuse, NY : Workers performing roofing activities on a 12:12 pitch roof and 9:12 pitch roof without utilizing fall protection were exposed to falls of greater than 6 feet.
Recent events (2)
  • — I (S) $2275
  • — Z (S) $4978

1926.1051 A

Serious Gravity 5 1 instance 7 exposed
Issued
Penalty
Initial $3318.00 · Current $1515.00 Reduced
29 CFR  1926.1051(a): Stairways or ladders were not provided at all personnel points of access where there was a break in elevation of 19 inches (48 cm) or more, and no ramp, runway, sloped embankment, or personnel hoist was provided.   a) On or about 08/08/2024, on the site located at 1119 Euclid Ave, Syracuse, NY : Employees were not provided stairways or ladders to access the second story of the residential home and instead were utilizing the RGC Hoist Platform as a ladder.
Recent events (2)
  • — I (S) $1515
  • — Z (S) $3318

View TOPTIER ROOFING LLC's full OSHA safety record →