1,224,460Inspections Most recent open 2026-07-13 Last loaded 2026-07-16
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Inspection: RIVER CITY SOLUTIONS, LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of RIVER CITY SOLUTIONS, LLC in 8916 RAINBOW HIGHWAY, WEST SALEM, OH 44287 (NAICS 321920). OSHA activity number 347832123.

Watch River City Solutions, LLC — free Get an email when a new federal OSHA severe-injury report for River City Solutions, LLC is published. One employer, no account, unsubscribe in one click.
Site address
8916 RAINBOW HIGHWAY
City
WEST SALEM
State
OH
ZIP
44287
Mailing
8916 RAINBOW HIGHWAY, WEST SALEM, OH 44287
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
321920
Employees
39
Ownership type
A

3 citations on file for this inspection.

1910.147 C05 II

Serious Gravity 5 1 instance 6 exposed
Issued
Penalty
Initial $8067.00 · Current $8067.00
29 CFR 1910.147(c)(5)(ii): Lockout devices and tagout devices were not singularly identified:   On or about October 22, 2024, the employer failed to ensure that when maintenance tasks were performed by authorized employees, that the lockout/tagout devices were singularly identified with the name of the employee who had isolated the electrical energy source on the Powermatic CS18 Upcut/Chop Saw and the Smetco Pallet Dismantler.
Recent events (2)
  • — I (S) $8067
  • — Z (S) $8067

1910.147 C06 I

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $8067.00 · Current $0.00 Reduced
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed:   On or about October 22, 2024, the employer did not ensure periodic inspections of energy control procedures were conducted annually, including a review of each authorized employee's responsibilities under the energy control procedures.  Authorized employees are required to conduct and direct service and maintenance activities on machinery including the Powermatic CS-18 Upcut/Chop Saw & Smetco Pallet Disassembler, with energy sources including, but not limited to, Electrical, Pneumatic, and Hydraulic.
Recent events (2)
  • — I (S) $0
  • — Z (S) $8067

1910.212 A01

Serious Gravity 10 1 instance 2 exposed
Issued
Penalty
Initial $11292.00 · Current $7904.00 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:  On or about October 14, 2024, the employer did not ensure one or more methods of machine guarding were provided to protect the operator and other employees working at the Powermatic CS-18 Upcut/Chop Saw, when employees utilize a foot pedal to power the upcut saw blade with the ability to have their hands underneath of the guard and within the point of operation. The existing guard was ineffective and resulted in an amputation injury.
Recent events (2)
  • — I (S) $7904.4
  • — Z (S) $11292

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347832123.