NORTH LITTLE ROCK, AR —
OSHA Inspection: MID-SOUTH MASONRY, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of MID-SOUTH MASONRY, INC. in 1120 ROCKWATER BLVD, NORTH LITTLE ROCK, AR 72114 (NAICS 238140). OSHA activity number 347921363.
Where did this inspection happen?
- Establishment
- MID-SOUTH MASONRY, INC.
- Site address
- 1120 ROCKWATER BLVD
- City
- NORTH LITTLE ROCK
- State
- AR
- ZIP
- 72114
- Mailing
- P.O. BOX 506, DEXTER, MO 63841
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238140
- Employees
- 3
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.451 B01
- Issued
- May 27, 2025
- Penalty
- Initial $4,256 · Current $4,256
General-duty citation text
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii): a.) On or about December 4, 2024, scaffolds were used to construct brick columns where the scaffold planks were used to support plywood which did not cover the entire support in the Northeast, Southeast, Northwest, and Southwest columns.
Recent events (1)
- — Z (S) $4256
1926.451 B07
- Issued
- May 27, 2025
- Abate by
- Jun 23, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(b)(7): On scaffolds where platforms are overlapped to create a long platform, the overlap did not occur only over supports: a) On or about December 4, 2024, scaffolds were used to construct brick columns where the boards were placed over other boards but not supports on the masonry scaffolds at the Northeast, Southeast, Northwest, and Southwest columns.
Recent events (1)
- — Z (S) $0
1926.451 C02
- Issued
- May 27, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(c)(2):Supported scaffold poles, legs, posts, frames, or uprights did not bear on base plates and mud sills or other adequate firm foundation: a) On or about December 4, 2024, scaffolds were used to construct brick columns where the base plates were directly on the ground surface in the Southeast and Southwest columns.
Recent events (1)
- — Z (S) $0
1926.452 C02
- Issued
- May 27, 2025
- Penalty
- Initial $4,256 · Current $4,256
General-duty citation text
29 CFR 1926.452(c)(2):Tubular welded frames and panels were not braced by cross, horizontal, or diagonal braces, or combination thereof, which would have secured vertical members together laterally: a) On or about December 4, 2024, scaffolds were used to construct brick columns where on the second level cross bracing was not installed on the sides facing the columns.
Recent events (1)
- — Z (S) $4256
More inspections at Mid-South Masonry, INC.
View Mid-South Masonry, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238140)
More inspections in AR
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347921363.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.