COUNTRYSIDE, IL —
OSHA Inspection: NYCO PRODUCTS COMPANY
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of NYCO PRODUCTS COMPANY in 5332 DANSHER ROAD, COUNTRYSIDE, IL 60525 (NAICS 325611). OSHA activity number 347982043.
Where did this inspection happen?
- Establishment
- NYCO PRODUCTS COMPANY
- Site address
- 5332 DANSHER ROAD
- City
- COUNTRYSIDE
- State
- IL
- ZIP
- 60525
- Mailing
- 5332 DANSHER ROAD, COUNTRYSIDE, IL 60525
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 325611
- Employees
- 49
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.147 D
- Issued
- Abate by
- Penalty
- Initial $6620.00 · Current $3750.00 Reduced
General-duty citation text
29 CFR 1910.147(d): The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6): a. On or about November 16, 2024, at the Pail Line, an employee was exposed to machine hazards associated with moving parts during the servicing and/or maintenance of a Pacer Series "G" sump pump, ultimately resulting in a partial amputation to left ring fingertip. The employer failed to implement energy control application steps as the machine was not shut down or turned off to perform the servicing work [per the 1910.147(d)(2) requirements]. As a result, the remaining applicable energy control elements, involving machine isolation [(d)(3)], LOTO device application [(d)(4)], dissipation of residual energy [(d)(5)((i)], and verification of isolation [(d)(6)], were not implemented to protect employees from machine servicing hazards.
Recent events (2)
- — I (S) $3750
- — Z (S) $6620
1910.303 B01
- Issued
- Penalty
- Initial $6620.00 · Current $3750.00 Reduced
General-duty citation text
29 CFR 1910.303(b)(1): Electrical equipment was not free from recognized hazards that were likely to cause death or serious physical harm to employees. a. On or about November 16, 2024, at the Pail Line, employees were required to access a control panel to manually operate the automatic-off-manual toggle switches for the Pacer "G" series sump pumps, thereby being exposing to electrical hazards associated with energized wires.
Recent events (2)
- — I (S) $3750
- — Z (S) $6620
1910.147 C06 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed. a. On or about November 16, 2024, in the facility, the employer did not conduct a periodic inspection of the energy control procedures to ensure that the procedure and requirements of this standard were being followed. Employees were thereby exposed to the hazards associated with unexpected re-energization of equipment.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at NYCO PRODUCTS COMPANY
CHICAGO, IL—1985-05-02
NYCO PRODUCTS COMPANY
View NYCO PRODUCTS COMPANY's full OSHA safety record →
More inspections in this industry (NAICS 325611)
PORTLAND, OR—2026-06-22
317744499 - LATHERING GOODNESS CO LLC
VERO BEACH, FL—2026-06-16
HOTSY TOTSY SOAP CO
MONTGOMERY, IL—2026-05-14
VVF ILLINOIS SERVICES, LLC
HARRODSBURG, KY—2026-05-05
69091 - EARTH BREEZE INC
SPRINGDALE, AR—2026-03-16
ROCKLINE INDUSTRIES, INC.
More inspections in IL
BLOOMINGTON, IL—2026-07-13
UNKNOWN CONTRACTOR