Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: AMBRELL CORPORATION

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of AMBRELL CORPORATION in 1655 LYELL AVENUE, ROCHESTER, NY 14606 (NAICS 333994). OSHA activity number 348032517.

Watch Ambrell Corporation — free Get an email when a new federal OSHA severe-injury report for Ambrell Corporation is published. One employer, no account, unsubscribe in one click.
Establishment
AMBRELL CORPORATION
Site address
1655 LYELL AVENUE
City
ROCHESTER
State
NY
ZIP
14606
Mailing
1655 LYELL AVENUE, ROCHESTER, NY 14606
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
333994
Employees
65
Ownership type
A

12 citations on file for this inspection.

1910.132 D01

Serious Gravity 1 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $4220.00 · Current $3165.00 Reduced
29 CFR  1910.132(d)(1):The employer did not assess the workplace to determine if hazards are present, or are likely to be present, which necessitate the use of personal protective equipment (PPE):  a) Brazing room: On or about 02/10/2025, the employer did not assess the hazards such as, but not limited to torch brazing and soldering which necessitate the use of personal protective equipment such as eye protection having rated shaded lenses to prevent eye injury.  ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
  • — I (S) $3165
  • — Z (S) $4220

1910.133 A05

Serious Gravity 1 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.133(a)(5): The employer did not ensure that each affected employee used equipment with filter lenses that had a shade number appropriate for the work being performed for protection from injurious light radiation:  a) Brazing room: On or about 02/10/2025, the employer did not ensure that employees used eye protection with filter lenses having minimum protective shade number 3, appropriate for protection from injurious light radiation when torch brazing work was performed.  b) Brazing room: On or about 02/10/2025, the employer did not ensure that employees used eye protection with filter lenses having minimum protective shade number 2, appropriate for protection from injurious light radiation when torch soldering work was performed.  ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.252 B02 I B

Serious Gravity 1 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.252(b)(2)(i)(B): Goggles or other suitable eye protection were not used during all gas welding or oxygen cutting operations:   a) Brazing room: On or about 02/10/2025, the employer did not ensure  use of suitable eye protection with filter lenses having minimum protective shade number 3, suitable for protection from injurious light radiation when torch brazing work was performed.  b) Brazing room: On or about 02/10/2025, the employer did not ensure  use of suitable eye protection with filter lenses having minimum protective shade number 2, suitable for protection from injurious light radiation when torch soldering work was performed.  ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.253 B01 II

Serious Gravity 1 2 instances 3 exposed
Issued
Abate by
Penalty
Initial $4220.00 · Current $3165.00 Reduced
29 CFR  1910.253(b)(1)(ii):Compressed gas cylinders were not legibly marked, for the purpose of identifying the gas content, with either the chemical or the trade name of the gas;  a)Warehouse/docking area: On or about 02/10/2025, compressed gas cylinder stored for brazing and for waste removal were not legibly marked for the purpose of identifying the gas content.  b)Brazing room: On or about 02/10/2025, compressed gas cylinders used for torch brazing and soldering were not legibly marked for the purpose of identifying the gas content.  ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
  • — I (S) $3165
  • — Z (S) $4220

1910.1200 E01

Serious Gravity 1 1 instance 65 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.1200(e)(1):The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met:  a) Ambrell Corporation: On or about 02/10/2025, the employer did not develop and maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met.  A written program should include descriptions of how the criteria for:      1.   Labeling and other forms of warning;      2.   Material Safety Data Sheets AND      3.   Employee information and training will be met. Additionally, a list of hazardous chemicals known to be present in the workplace must be compiled.  Methods used to inform employees of the hazards associated with non-routine tasks and the informing of contractors of workplace hazard must also be addressed.  The written program must be made available upon request.  ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.1200 F06 II

Serious Gravity 1 2 instances 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.1200(f)(6)(ii): Except as provided in 29 CFR 1910.1200(f)(7) and 29 CFR 1910.1200(f)(8), the employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the product identifier and words, pictures, symbols, or combination thereof, which provide at least general information regarding the hazards of the chemicals and which, in conjunction with the other information immediately available to employees under the hazard communication program, would provide employees with the specific information regarding the physical and health hazards of the hazardous chemical;  a) Warehouse/docking area: On or about 02/10/2025, compressed gas cylinder stored for brazing and for waste removal were not labeled.  b) Brazing room: On or about 02/10/2025, compressed gas cylinders used for torch brazing and soldering were not labeled.  ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.253 B04 III

Serious Gravity 5 1 instance 6 exposed
Issued
Abate by
Penalty
Initial $5627.00 · Current $4220.00 Reduced
1910.253(b)(4)(iii) Oxygen cylinders in storage shall be separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one-half hour:  a) Warehouse/docking area: On or about 02/10/2025, 2 propane and 2 oxygen cylinders were stored together in the same cage, exposing employees to a fire hazard.  ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
  • — I (S) $4220.25
  • — Z (S) $5627

1910.333 A02

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $7035.00 · Current $5276.00 Reduced
29 CFR  1910.333(a)(2): Where exposed live parts were not deenergized (i.e., for reasons of increased or additional hazards or infeasibility), other safety-related work practices were not used to protect employees who could be exposed to the electrical hazards involved:  a) Electric Test Area:  On or about 02/10/2025, employees were within an arm's reach (~2ft) of unguarded, not deenergized electrical parts (480V) while visually inspecting and testing EkoHeat power units without being protected by other safety related work practices.  ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
  • — I (S) $5276.25
  • — Z (S) $7035

1910.335 A01 I

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.335(a)(1)(i):Employees working in areas where there were potential electrical hazards were not provided with electrical protective equipment that was appropriate for the specific parts of the body that needed to be protected and for the work being performed:  a) Electric Test Area:  On or about 02/10/2025, employees were performing testing of EkoHeat power units with side panels removed, exposing them to energized electrical hazards (480v), were not provided electrical protective equipment including insulated gloves, arc flash clothing,  arc-rated face shields, and electrical safety shoes.  ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.335 A02 II

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.335(a)(2)(ii): Protective shields, protective barriers, or insulating materials were not used to protect each employee from shock, burns, or other electrically related injuries while that employee was working near exposed energized parts;  a) Electric Test Area:  On or about 02/10/2025, employees performing testing of EkoHeat power units without side panels and within arm's reach (~2ft)of unguarded high voltage electrical components (480V), were not protected from electrical hazards by protective shields, barriers, or insulating materials, exposing employees to shock, burns, other electrically related injuries, or death.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1904.32 B06

Other-than-serious 1 instance 65 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1904.32(b)(6):The Summary of Work-Related Injuries and Illnesses (OSHA Form 300A or equivalent) for the previous year was not posted between February 1 and April 30.  a)	Ambrell Corporation: On or about 02/10/2025, the previous year summary log of illnesses and injuries was not posted in a conspicuous place.  ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.157 E02

Other-than-serious 1 instance 65 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.157(e)(2): Portable fire extinguishers were not visually inspected at least monthly:  a) Ambrell Corporation facility wide: On or about 02/10/2025, portable fire extinguishers were not visually inspected at least monthly.  ABATEMENT CERTIFICATION REQUIRED