AMHERST, NY —
OSHA Inspection: KISTLER INSTRUMENT CORPORATION
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of KISTLER INSTRUMENT CORPORATION in 75 JOHN GLENN DR., AMHERST, NY 14228 (NAICS 334515). OSHA activity number 348171109.
Where did this inspection happen?
- Establishment
- KISTLER INSTRUMENT CORPORATION
- Site address
- 75 JOHN GLENN DR.
- City
- AMHERST
- State
- NY
- ZIP
- 14228
- Mailing
- 75 JOHN GLENN DR., AMHERST, NY 14228
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 334515
- Employees
- 61
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.212 A01
- Issued
- Abate by
- Penalty
- Initial $7235.00 · Current $5426.00 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by rotating parts: a) On or about 04/10/2025, in the Machine Shop Room, employees were exposed to caught-by hazards when operating the HARDINGE #3 lathe without a guard over the Headstock spindle. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $5426.25
- — Z (S) $7235
1910.242 B
- Issued
- Abate by
- Penalty
- Initial $5426.00 · Current $4070.00 Reduced
General-duty citation text
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.: a) On or about 04/10/2025, in the Machine Shop Room, employees were exposed to flying debris and internal injuries when using compressed air for cleaning parts with the nozzle pressure reaching approximately 91 p.s.i.. No safeguards were in place to limit the pressure of a back-pressure buildup in case the nozzle is obstructed or dead-ended. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $4069.5
- — Z (S) $5426
More inspections in this industry (NAICS 334515)
DRACUT, MA—2026-07-07
CROWN BATTERY
LAS VEGAS, NV—2026-06-25
FOWLER ELECTRIC LTD
ACCIDENT, MD—2026-03-18
DOBLE ENGINEERING COMPANY
TINLEY PARK, IL—2025-03-20
S & C DISTRIBUTION COMPANY
BONNEY LAKE, WA—2025-02-13
WA317984459 - EHE ACQUISITION CORPORATION
More inspections in NY
POUGHKEEPSIE, NY—2026-07-13
MARCO BOARD HOUSE, INC.
CORTLANDT MANOR, NY—2026-07-13
LG BUILDERS INC.
CORTLANDT MANOR, NY—2026-07-13
RJW RENOVATIONS, LLC
HEMPSTEAD, NY—2026-07-13
NYSDOCCS NASSAU AREA OFFICE
NIAGARA FALLS, NY—2026-07-10
NTVI FEDERAL INC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348171109.