Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: PREMIUM SUBSEA, LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of PREMIUM SUBSEA, LLC in 22502 PARK RD., TOMBALL, TX 77377 (NAICS 332911). OSHA activity number 348180571.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Premium Subsea, LLC — free Get an email when a new federal OSHA severe-injury report for Premium Subsea, LLC is published. One employer, no account, unsubscribe in one click.
Establishment
PREMIUM SUBSEA, LLC
Site address
22502 PARK RD.
City
TOMBALL
State
TX
ZIP
77377
Mailing
14406 SPRING MOUNTAIN DRIVE, TOMBALL, TX 77377
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332911
Employees
15
Ownership type
A

2 citations on file for this inspection.

1910.212 A01

Serious Gravity 5 1 instance 2 exposed
Issued
Aug 25, 2025
Penalty
Initial $2,838 · Current $1,703 Reduced
29 CFR  1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:  On or about April 15, 2025, and at times prior there to, in the Machine Shop Area, employees operated a horizontal band saw with the unused portions of the blade unguarded while cut materials.
Recent events (2)
  • — I (S) $1702.8
  • — Z (S) $2838

1910.303 B02

Serious Gravity 5 1 instance 3 exposed
Issued
Aug 25, 2025
Abate by
Aug 29, 2025
Penalty
Initial $2,270 · Current $1,362 Reduced
29 CFR  1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:  On or about April 15, 2025, and at times prior there to, in the machine shop area; employee(s) utilized a relocatable power taps that was plugged into an extension cord to provide power to a pedestal fan while performing machine milling work.
Recent events (2)
  • — I (S) $1362
  • — Z (S) $2270

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348180571.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.