On , OSHA opened a complaint safety inspection of HOT ACTION SPORTSWEAR, INC. in 307 DIVISION AVENUE UNIT 12, ORMOND BEACH, FL 32174 (NAICS 323113). OSHA activity number 348493594.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- HOT ACTION SPORTSWEAR, INC.
- Site address
- 307 DIVISION AVENUE UNIT 12
- City
- ORMOND BEACH
- State
- FL
- ZIP
- 32174
- Mailing
- 307 DIVISION AVENUE UNIT 12, ORMOND BEACH, FL 32174
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 323113
- Employees
- 27
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.303 G02 I B
- Issued
- Mar 2, 2026
- Abate by
- Apr 6, 2026
- Penalty
- Initial $8,276 · Current $4,962 Reduced
General-duty citation text
29 CFR 1910.303(g)(2)(i)(B): Except as elsewhere required or permitted by this standard, live parts of electrical equipment operating at 50 volts or more was not guarded by suitable permanent, substantial partitions or screens so arranged so that only qualified persons would have access to the space within reach of the live parts. Any openings in such partitions or screens were not so sized and located that persons were not likely to come into accidental contact with the live parts or to bring conducting objects into contact with them: a. Throughout the production area: On or about September 10, 2025 and at times prior, the employer exposed employees to electrical hazards, in that workers were allowed to walk and work around live parts of a Centurian Automatic Multicolor Textile Printer operating at 50 volts or more, and the employer did not guard the equipment by a form of approved enclosure.
Recent events (2)
- — I (S) $4962
- — Z (S) $8276
1910.305 A02 V C
- Issued
- Mar 2, 2026
- Abate by
- Apr 6, 2026
- Penalty
- Initial $8,276 · Current $4,962 Reduced
General-duty citation text
29 CFR 1910.305(a)(2)(v)(C): Branch-circuit conductors were laid on the floor: a. Throughout the production area: On or about September 10, 2025 and at times prior, the employer exposed employees to electrical hazards, in that employees were allowed to walk and work over branch-circuit conductors laying on the floor.
Recent events (2)
- — I (S) $4962
- — Z (S) $8276
1910.305 B01 II
- Issued
- Mar 2, 2026
- Abate by
- Apr 6, 2026
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed: a. Throughout the production area: On or about September 10, 2025 and at times prior, the employer exposed employees to electrical hazards, in that employees were allowed to walk and work near unused openings in cabinets and boxes that were not effectively closed.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.305 B02 I
- Issued
- Mar 2, 2026
- Abate by
- Apr 6, 2026
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(b)(2)(i): Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy: a. Throughout the production area: On or about September 10, 2025 and at times prior, the employer exposed employees to electrical hazards, in that employees were allowed to walk and work near outlet boxes missing cover faceplate or fixtured canopy.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.305 G01 IV A
- Issued
- Mar 2, 2026
- Abate by
- Apr 6, 2026
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and cables were used as a substitute for the fixed wiring of a structure: a. Throughout the production area: On or about September 10, 2025 and at times prior, the employer exposed employees to electrical hazards, in that employees used flexible temporary cables as permanent wiring providing current to multiple equipment.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.305 G01 IV C
- Issued
- Mar 2, 2026
- Abate by
- Apr 6, 2026
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(C): Flexible cords and cables were run through doorways, windows, or similar openings: a. Throughout the production area: On or about September 10, 2025 and at times prior, the employer exposed employees to electrical hazards, in that employees used flexible cords which were run through openings in and out of the work area.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at HOT Action Sportswear, INC.
View HOT Action Sportswear, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 323113)
More inspections in FL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348493594.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.