SAINT GABRIEL, LA —
OSHA Inspection: MEXICHEM FLUOR INC.
Unprogrammed Related inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Related safety inspection of MEXICHEM FLUOR INC. in 4990B ICI ROAD, SAINT GABRIEL, LA 70776 (NAICS 325120). OSHA activity number 348627829.
Where did this inspection happen?
- Establishment
- MEXICHEM FLUOR INC.
- Site address
- 4990B ICI ROAD
- City
- SAINT GABRIEL
- State
- LA
- ZIP
- 70776
- Mailing
- 4990B ICI ROAD, SAINT GABRIEL, LA 70776
What kind of inspection was it?
- Inspection type
- Unprogrammed Related (G)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 325120
- Employees
- 90
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.22 A01
- Issued
- Abate by
- Penalty
- Initial $9931.00 · Current $7945.00 Reduced
General-duty citation text
29 CFR 1910.22(a)(1): The employer did not ensure that all places of employment, passageways, storerooms, service rooms, and walking-working surfaces are kept in a clean, orderly, and sanitary condition: a) On or about November 28, 2025, in the HF Area Near Flange E510, the employer failed to ensure the grade-level work area was maintained in a clean condition before employees were required to work in horizontal positions.
Recent events (2)
- — I (S) $7944.8
- — Z (S) $9931
1910.132 F01 IV
- Issued
- Abate by
- Penalty
- Initial $9931.00 · Current $9931.00
General-duty citation text
29 CFR 1910.132(f)(1)(iv): Employee(s) required to use PPE by this section were not trained to know the limitations of PPE: a) On or about November 28, 2025, in the HF Area Near Flange E510, employees who were engaged in rebuilding a flange were not trained on the potential for cross-contamination of the chemical suit during donning and doffing procedures.
Recent events (2)
- — I (O) $9931
- — Z (S) $9931
More inspections at MEXICHEM FLUOR INC.
SAINT GABRIEL, LA—2025-11-19
MEXICHEM FLUOR INC.
View MEXICHEM FLUOR INC.'s full OSHA safety record →
More inspections in this industry (NAICS 325120)
GLENDALE, AZ—2026-06-04
URX2026XMG193X0055 - A-GAS US INC.
MAGNA, UT—2026-06-01
PRAXAIR INC
BEULAH, ND—2026-05-27
DAKOTA GASIFICATION COMPANY
MARTINEZ, CA—2026-05-08
NIPPON SANSO MATHESON, INC.
TEXAS CITY, TX—2026-05-07
LINDE INC.
More inspections in LA
AMELIA, LA—2026-07-10
CONRAD SHIPYARD, LLC
MORGAN CITY, LA—2026-07-10
G4 SERVICES LLC
PIERRE PART, LA—2026-07-08
DOLLAR GENERAL
LAKE CHARLES, LA—2026-07-01
GULF COAST FORENSIC SOLUTIONS
BATON ROUGE, LA—2026-06-26
TRAFFIC CONTROL PRODUCTS CO. OF LOUISIANA, INC.
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348627829.