ATLANTIC CITY, NJ —
OSHA Inspection: CARLTON STRUCTURAL SERVICES CORP.
Federal Agency inspection · Safety discipline
At a glance
On , OSHA opened a federal Agency safety inspection of CARLTON STRUCTURAL SERVICES CORP. in 1825 MURRAY AVE, ATLANTIC CITY, NJ 08401 (NAICS 238110). OSHA activity number 348628777.
Where did this inspection happen?
- Establishment
- CARLTON STRUCTURAL SERVICES CORP.
- Site address
- 1825 MURRAY AVE
- City
- ATLANTIC CITY
- State
- NJ
- ZIP
- 08401
- Mailing
- 356 HAPPY TRAILS ROAD, LEXINGTON, NC 27295
What kind of inspection was it?
- Inspection type
- Federal Agency (M)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238110
- Employees
- 6
- Ownership type
- A
Citations
5 citations on file for this inspection.
5A0001
- Issued
- Abate by
- Penalty
- Initial $4965.00 · Current $4965.00
General-duty citation text
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to struck-by/Collapse hazards from an unsupported gin pole during demolition of a communication tower. (a) 1825 Murray Ave, Atlantic City, NJ 08401: Employees were removing a 50 foot tall antenna structure utilizing a 68 foot tall Tower Equipment Co PT21 gin pole that was erected and secured to a 300 foot tall AM Blu Knox communication tower structure. The gin pole failed as the antenna was attempted to be lowered fatally striking an employee on or about 12/05/2025. (b) 1825 Murray Ave, Atlantic City, NJ 08401: Employees were removing a 50 foot tall antenna structure utilizing a 68 foot tall Tower Equipment Co PT21 gin pole that was erected and secured to a 300 foot tall AM Blu Knox communication tower structure. The gin pole was secured to the communication tower using nylon slings which were not protected or padded against abrasion. The gin pole failed as the antenna was attempted to be lowered fatally striking an employee on or about 12/05/2025. NOTE: IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM, FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (1)
- — Z (S) $4965
19260021 B02
- Issued
- Abate by
- Penalty
- Initial $4965.00 · Current $4965.00
General-duty citation text
29 CFR 1926.21(b)(2): The employer did not instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his/her environment to control or eliminate any hazards or other exposure to illness or injury: (a) 1825 Murray Ave, Atlantic City, NJ 08401: Employees were removing a 50 foot tall antenna structure utilizing a 68 foot tall Tower Equipment Co PT21 gin pole that was erected and secured to a 300 foot tall AM Blu Knox communication towers structure and were not instructed in the recognition and avoidance of unsafe conditions and regulations to avoid injuries and death on or about 12/05/2025. NOTE: IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM, FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (1)
- — Z (S) $4965
19260251 A06
- Issued
- Abate by
- Penalty
- Initial $4965.00 · Current $4965.00
General-duty citation text
29 CFR 1926.251(a)(6): Each day before being used, and during use, where service conditions warrant, the sling and all fastenings and attachments were not inspected for damage or defects by a competent person, and damaged or defective slings were not immediately removed from service: (a) 1825 Murray Ave, Atlantic City, NJ 08401: Employees were removing a 50 foot tall antenna structure utilizing a 68 foot tall Tower Equipment Co PT21 gin pole that was erected and secured to a 300 foot tall AM Blu Knox communication tower structure did not inspect the Liftall Tuflex Nylon slings for damage before being used. EN60 Tuflex Endless Round Slings and EN150 Tuflex Endless Round Slings and were used to secure the Gin Pole to the Communication Tower and each had visible damage but were still used on or about 12/05/2025. NOTE: IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM, FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (1)
- — Z (S) $4965
19260251 E08 III
- Issued
- Abate by
- Penalty
- Initial $4965.00 · Current $4965.00
General-duty citation text
29 CFR 1926.251(e)(8)(iii): Synthetic web slings were not immediately removed from service when any of the following conditions were present: snags, punctures, tears or cuts. (a) 1825 Murray Ave, Atlantic City, NJ 08401: Employees were removing a 50 foot tall antenna structure utilizing a 68 foot tall Tower Equipment Co PT21 gin pole that was erected and secured to a 300 foot tall AM Blu Knox communication tower structure did not remove synthetic web slings with damage, punctures and cuts from being used to hoist and secure the gin pole to the communication tower on or about 12/05/2025. NOTE: IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM, FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (1)
- — Z (S) $4965
19261053 B17
- Issued
- Abate by
- Penalty
- Initial $4256.00 · Current $4256.00
General-duty citation text
29 CFR 1926.1053(b)(17): Fixed ladders with structural defects, such as, but not limited to, broken or missing rungs, cleats, or steps, broken or split rails, or corroded components, were not withdrawn from service until repaired: (a) 1825 Murray Ave, Atlantic City, NJ 08401: Employees were removing a 50 foot tall antenna structure utilizing a 68 foot tall Tower Equipment Co PT21 gin pole that was erected and secured to a 300 foot tall AM Blu Knox communication tower structure and were climbing the steel ladder mounted to the communication tower that was severely rusted and some areas had sections of missing rungs and side rails on or about 12/05/2025. NOTE: IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM, FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (1)
- — Z (S) $4256
More inspections in this industry (NAICS 238110)
MERIDIAN, ID—2026-07-10
DIAMOND CONCRETE, LLC
WEBSTER, TX—2026-07-09
ZITRO CONCRETE CONSTRUCTION LLC
CHICAGO, IL—2026-07-09
GOEBEL FORMING, LLC
SAN ANTONIO, TX—2026-07-08
URBAN CONCRETE CONTRACTORS LTD
BRITTON, MI—2026-07-07
COOK FOUNDATION & FLATWORK, INC.
More inspections in NJ
FANWOOD, NJ—2026-07-10
CLOSET FACTORY
ISELIN, NJ—2026-07-09
DELTA HOTELS WOODBRIDGE
CARTERET, NJ—2026-07-09
UNIUNI LOGISTICS INC
EWING, NJ—2026-07-09
TOWNSHIP OF EWING - DEPARTMENT OF PUBLIC WORKS
WESTFIELD, NJ—2026-07-09
SCENIC LANDSCAPING
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348628777.