1,224,460Inspections Most recent open 2026-07-13 Last loaded 2026-07-16
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Inspection: LIBERTY ELECTRONICS, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of LIBERTY ELECTRONICS, INC. in 189 HOWARD STREET, FRANKLIN, PA 16323 (NAICS 334412). OSHA activity number 348636036.

Site address
189 HOWARD STREET
City
FRANKLIN
State
PA
ZIP
16323
Mailing
189 HOWARD STREET, FRANKLIN, PA 16323
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
334412
Employees
350
Ownership type
A

1 citation on file for this inspection.

1910.213 A15

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $12059.00 · Current $6500.00 Reduced
29 CFR  1910.213(a)(15): Combs (feather boards) or suitable jigs shall be provided at the workplace for use when a standard guard cannot be used, as in dadoing, grooving, jointing, moulding, and rabbeting.  a.)  Liberty Electronics, Inc.;  area 5, Production area - On or about 11/20/25, and at times prior thereto,  a two block technique was not utilized when processing the wood on the Craftsman Jointer.  ABATEMENT CERTIFICATION REQUIRED: Abatement certification is required within 10 days after the abatement date noted on the citation (see below).  This certification shall include a statement that abatement is complete, the date abatement was completed, method of abatement, and state that employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $6500
  • — Z (S) $12059