1,224,460Inspections Most recent open 2026-07-13 Last loaded 2026-07-16
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Inspection: PERSANT CONSTRUCTION COMPANY, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of PERSANT CONSTRUCTION COMPANY, INC. in 12375 SW 248TH ST COCONUT PALM DR - WEST BOUND, HOMESTEAD, FL 33032 (NAICS 237110). OSHA activity number 348636572.

Site address
12375 SW 248TH ST COCONUT PALM DR - WEST BOUND
City
HOMESTEAD
State
FL
ZIP
33032
Mailing
13175 SOUTHWEST 124TH AVENUE, MIAMI, FL 33186
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Last modified
Data loaded
NAICS code
237110
Employees
6
Ownership type
A

9 citations on file for this inspection.

1926.28 A

Serious Gravity 1 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $3376.00 · Current $2026.00 Reduced
29 CFR  1926.28(a): The employer did not require the wearing of appropriate personal protective equipment in all operations where there is an exposure to hazardous conditions:  a) On or about December 4, 2025, at the worksite located at the westbound sidewalk, 12375 SW 248th St, Homestead, FL, 33032, the employer did not ensure hand protection was used by employees who were exposed to abrasion and puncture hazards while working inside of a trench without protective gloves.
Recent events (2)
  • — I (S) $2025.6
  • — Z (S) $3376

1926.100 A

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $4502.00 · Current $2701.00 Reduced
29 CFR  1926.100(a): Employees working in areas where there is a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns, was not protected by protective helmets:  a) On or about December 4, 2025, at the worksite located at the westbound sidewalk, 12375 SW 248th St, Homestead, FL, 33032, the employer did not ensure the use of head protection for employees who were exposed to struck-by hazards while working inside of a trench and underneath an excavator's bucket  (i.e. John Deere, Model: 350 G, Serial Number: 1FF350GXPJF813253), without helmets.
Recent events (2)
  • — I (S) $2701.2
  • — Z (S) $4502

1926.416 A01

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $5628.00 · Current $3377.00 Reduced
29 CFR  1926.416(a)(1): An employee was permitted to work in proximity to an electric power circuit that the employee could contact in the course of work and was not protected against electric shock by deenergizing the circuit and grounding it or by guarding it effectively by insulation or other means:  a) On or about December 4, 2025, at the worksite located at the westbound sidewalk, 12375 SW 248th St, Homestead, FL, 33032, an employee was exposed to an electrocution hazard while operating an excavator's arm (i.e. John Deere, Model: 350 G, Serial Number: 1FF350GXPJF813253), within 10 feet of 13.2-kV overhead power line.
Recent events (2)
  • — I (S) $3376.8
  • — Z (S) $5628

1926.651 E

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $6753.00 · Current $4052.00 Reduced
29 CFR  1926.651(e): Employees were not prohibited to be underneath loads handled by lifting or digging equipment.  Employees were not required to stand away from any vehicle being loaded or unloaded to avoid being struck by any spillage or falling materials:  a) On or about December 4, 2025, at the worksite located at the westbound sidewalk, 12375 SW 248th St, Homestead, FL, 33032, the employer did not ensure employees who were working underneath an excavator's bucket  (i.e. John Deere, Model: 350 G, Serial Number: 1FF350GXPJF813253) maintained a safe distance away from excavator's bucket while securing a concrete pipe in place, thus employees were exposed to crushed-by and struck-by hazards.
Recent events (2)
  • — I (S) $4051.8
  • — Z (S) $6753

1926.651 G02 I

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $6753.00 · Current $4052.00 Reduced
29 CFR  1926.651(g)(2)(i): Emergency rescue equipment, such as breathing apparatus, a safety harness and line, or a basket stretcher, was not readily available where hazardous atmospheric conditions existed:   a) On or about December 4, 2025, at the worksite located at the westbound sidewalk, 12375 SW 248th St, Homestead, FL, 33032, the employer did not ensure that emergency rescue equipment (Breathing apparatus, Safety harness/line and basket stretcher) were available for all work members who were performing sewer piping installation activities.
Recent events (2)
  • — I (S) $4051.8
  • — Z (S) $6753

1926.651 H01

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $5628.00 · Current $3377.00 Reduced
29 CFR  1926.651(h)(1): Employees were working in excavations in which there was accumulated water and adequate precautions had not been taken to protect employees against the hazards posed by water accumulation.  a) On or about December 4, 2025, at the worksite located at the westbound sidewalk, 12375 SW 248th St, Homestead, FL, 33032, employees were exposed to a drowning hazard while working inside of a trench filled with approximately 2 feet of water without a  water pumping system.
Recent events (2)
  • — I (S) $3376.8
  • — Z (S) $5628

1926.651 J02

Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $9268.00 · Current $5561.00 Reduced
29 CFR  1926.651(j)(2): Protection was not provided by placing and keeping excavated or other materials or equipment at least 2 feet (.61m) from the edge of excavations, or by the use of retaining devices that were sufficient to prevent materials or equipment from falling or rolling into excavations, or by a combination of both if necessary:  a) On or about December 4, 2025, at the worksite located at the westbound sidewalk, 12375 SW 248th St, Homestead, FL, 33032, employees were exposed to crushed-by and struck-by hazards while working inside a trench 8 feet deep without any cave-in protection to prevent and keep spoil pile materials and equipment at least 2 feet from the edge of excavation.
Recent events (2)
  • — I (S) $5560.8
  • — Z (S) $9268

1926.651 K02

Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $9268.00 · Current $5561.00 Reduced
29 CFR  1926.651(k)(2): The competent person found evidence of a situation that could result in possible cave-in, indications of failure of protective systems, hazardous atmospheres, or other hazardous conditions, exposed employees were not removed from the hazardous area until the necessary precautions have been taken to ensure their safety:  a) On or about December 4, 2025, at the worksite located at the westbound sidewalk, 12375 SW 248th St, Homestead, FL, 33032, the employer did not ensure employees were removed while working in a 8 feet trench without cave-in protection, thus exposing employees to crushed-by and struck-by hazards.
Recent events (2)
  • — I (S) $5560.8
  • — Z (S) $9268

1926.652 A01

Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $9268.00 · Current $5561.00 Reduced
29 CFR  1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system:   a) On or about December 4, 2025, at the worksite located at the westbound sidewalk, 12375 SW 248th St, Homestead, FL, 33032,  employees were exposed to a crushed-by and struck by hazards while working inside a trench 8 feet which was not provided with a protective system to prevent  cave-ins.
Recent events (2)
  • — I (S) $5560.8
  • — Z (S) $9268

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348636572.