JACKSONVILLE, FL —
OSHA Inspection: NEFTALI VAZQUEZ
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of NEFTALI VAZQUEZ in 11938 GENERATION AVE LOT 286, JACKSONVILLE, FL 32201 (NAICS 238170). OSHA activity number 348671579.
Where did this inspection happen?
- Establishment
- NEFTALI VAZQUEZ
- Site address
- 11938 GENERATION AVE LOT 286
- City
- JACKSONVILLE
- State
- FL
- ZIP
- 32201
- Mailing
- 5926 CAMARO DRIVE WEST, JACKSONVILLE, FL 32244
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238170
- Employees
- 3
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.102 A01
- Issued
- Penalty
- Initial $2128.00 · Current $2128.00
General-duty citation text
29 CFR 1926.102(a)(1): The employer did not ensure that each affected employee used appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids, caustic liquids, or chemical gases or vapors and at times prior thereto, workers were exposed to a struck by hazard while cutting concrete with a saw, without the use and wear of protective eyewear: a. At a temporary worksite, located at the east side of 11938 Generation Ave Lot 286 On or about January 7, 2026, the employer exposed employees to eye-injury struck-by hazards, in that protective eyewear was not utilized by employees while using metal hammers and nail guns for siding work.
Recent events (1)
- — Z (S) $2128
1926.451 B06
- Issued
- Penalty
- Initial $3547.00 · Current $3547.00
General-duty citation text
29 CFR 1926.451(b)(6): On scaffolds where scaffold planks are abutted to create a long platform, each abutted end shall rest on a separate support surface. This provision does not preclude the use of common support members, such as "T" sections, to support abutting planks, or hook on platforms designed to rest on common supports. a. At a temporary worksite, located at the east side of 11938 Generation Ave Lot 286 On or about January 7, 2026, the employer was exposing employees to a 10-11 foot fall hazard, in that the employees worked from a scaffold plank that was abutted to another plank and one end did not rest on a ladder jack support of the ladder jack scaffold system.
Recent events (1)
- — Z (S) $3547
1926.452 K05
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.452(k)(5): Scaffold platforms were bridged one to another: a. At a temporary worksite, located at the east side of 11938 Generation Ave Lot 286 On or about January 7, 2026, the employer was exposing employees to a 10-11 foot fall hazard, in that the employees worked from bridged scaffold planks on a ladder jack scaffold.
Recent events (1)
- — Z (S) $0
1926.451 G01 VII
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.451(g)(1)(vii): For all scaffolds not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, each employee was not protected by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section. a. At a temporary worksite, located at the east side of 11938 Generation Ave Lot 286 On or about January 7, 2026, the employer was exposing employees to a 10-11 foot fall hazard, in that the employees were not tied off when conducting siding work from a ladder jack scaffold and there were no other means of fall protection from the platform.
Recent events (1)
- — Z (S) $0
1926.100 A
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.100(a): Employees were not protected by protective helmets while working in areas where there was a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns: a. At a temporary worksite, located at the east side of 11938 Generation Ave Lot 286 On or about January 7, 2026, an employee was exposed to the hazard of being stuck- by falling objects, while working below siding installations activities without being protected by a protective helmet.
Recent events (1)
- — Z (O) $0
More inspections in this industry (NAICS 238170)
OXFORD, OH—2026-07-13
R&R SIDING LLC
WINSTON SALEM, NC—2026-07-10
161522 - MS SIDING LLC
SLINGER, WI—2026-07-10
DYLAN MATTHEW SHELLEY LLC
WINSTON SALEM, NC—2026-07-09
161514 - ALPHA OMEGA CONSTRUCTION GROUP, INC
ATLANTA, GA—2026-07-09
ESV CONSTRUCTION LLC
More inspections in FL
MARIANNA, FL—2026-07-13
PRIMETIME MOBILE MASONRY LLC
MELBOURNE, FL—2026-07-13
OMNIPOTENT BRANDS, LLC
QUINCY, FL—2026-07-13
WALMART
INDIAN ROCKS BEACH, FL—2026-07-10
UNKNOWN CONTRACTOR
CLEARWATER, FL—2026-07-10
ROOFTECH ROOFING & WATERPROOFING INC
Source