942,588Inspections Most recent open 2026-07-09 Last loaded 2026-07-13
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Inspection: CORE TECH INTERNATIONAL CORPORATION

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of CORE TECH INTERNATIONAL CORPORATION in 298 WASHINGTON DRIVE GUAM COMMUNITY COLLEGE, MANGILAO, GU 96913 (NAICS 212312). OSHA activity number 348676065.

Site address
298 WASHINGTON DRIVE GUAM COMMUNITY COLLEGE
City
MANGILAO
State
GU
ZIP
96913
Mailing
388 SOUTH MARINE CORPS DRIVE SUITE 400, TAMUNING, GU 96913
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
212312
Employees
339
Ownership type
A

4 citations on file for this inspection.

19260403 B02

Serious Gravity 1 1 instance 4 exposed
Issued
Penalty
Initial $7093.00 · Current $4965.00 Reduced
29 CFR  1926.403(b)(2): Installation and use. Listed, labeled, or certified equipment shall be installed and used in accordance with instructions included in the listing, labeling, or certification.  On or about January 7, 2026 in front of the office in the break area tent: A receptacle box, intended to be installed in  a wall, was wired onto the end of an extension cord and was used to power the microwave.
Recent events (2)
  • — I (S) $4965.1
  • — Z (S) $7093

19260405 J01 I

Serious Gravity 1 1 instance 4 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR  1926.405(j)(1)(i): Fixtures, lampholders, lamps, rosettes, or receptacles had live parts normally exposed to employee contact:  On or about January 7, 2026, in front of the office in the management container : A receptacle box mounted on the end of an extension cord used to power the microwave had an open knockout hole.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

19100305 G01 IV A

Other-than-serious 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:  On or about January 7, 2026 in front of the office: Flexible cords were used as fixed wiring for the lights at the break area tent.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

19260405 G02 IV

Other-than-serious 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1926.405(g)(2)(iv): Flexible cords were not connected to devices and fittings so that strain relief is provided to prevent pull from being directly transmitted to joints or terminal screws:  On or about January 7, 2026 in front of the office in the break area tent: The outer insulation to the flexible cord used to power the lights was pulled from the junction box exposing the inner wiring.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View CORE TECH INTERNATIONAL CORPORATION's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348676065.