DOUGLASSVILLE, PA —
OSHA Inspection: WOLF TECHNOLOGIES, LLC
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of WOLF TECHNOLOGIES, LLC in 551 OLD SWEDE ROAD, DOUGLASSVILLE, PA 19518 (NAICS 331512). OSHA activity number 348692302.
Where did this inspection happen?
- Establishment
- WOLF TECHNOLOGIES, LLC
- Site address
- 551 OLD SWEDE ROAD
- City
- DOUGLASSVILLE
- State
- PA
- ZIP
- 19518
- Mailing
- 551 OLD SWEDE ROAD, DOUGLASSVILLE, PA 19518
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Last modified
- Data loaded
Establishment context
- NAICS code
- 331512
- Employees
- 65
- Ownership type
- A
Citations
8 citations on file for this inspection.
1910.134 C01
- Issued
- Abate by
- Penalty
- Initial $9931.00 · Current $5000.00 Reduced
General-duty citation text
29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use: a) 551 Old Swede Road, Douglassville, PA 19518 - Leech Room: On or about January 15, 2026, employees were required to wear tight-fitting half facepiece respirators while working with hydrochloric acid and the employer did not implement a written respiratory protection program with worksite-specific procedures. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states that employees and their representatives were informed of this abatement.
Recent events (2)
- — I (S) $5000
- — Z (S) $9931
1910.134 D01 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.134(d)(1)(i): Selection of appropriate respirators was not based on the respiratory hazard(s) to which the worker was exposed and user factors that affect respirator performance and reliability: a) 551 Old Swede Road, Douglassville, PA 19518 - Leech Room: On or about January 15, 2026, employees were required to wear tight-fitting half facepiece respirators (Miller LPR-100 Half Mask Respirator, M/L (ML00995) with P100 cartridges) while working with hydrochloric acid and the cartridge selected was not effective for acid gases. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states that employees and their representatives were informed of this abatement.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.134 E01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: a) 551 Old Swede Road, Douglassville, PA 19518 - Leech Room: On or about January 15, 2026, employees were required to wear tight-fitting half facepiece respirators while working with hydrochloric acid and had not been medically evaluated by a physician or other licensed healthcare professional (PLHCP). Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states that employees and their representatives were informed of this abatement.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.134 F02
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.134(f)(2): Employee(s) using tight-fitting facepiece respirators were not fit tested prior to initial use of the respirator: a) 551 Old Swede Road, Douglassville, PA 19518 - Leech Room: On or about January 15, 2026, employees were required to wear tight-fitting half facepiece respirators while working with hydrochloric acid and had not been fit tested prior to initial use of the respirator. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states that employees and their representatives were informed of this abatement.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.134 K
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.134(k): The employer did not provide comprehensive, understandable training which did not occur annually and/or more often if necessary: a) 551 Old Swede Road, Douglassville, PA 19518 - Leech Room: On or about January 15, 2026, employees were required to wear tight-fitting half facepiece respirators while working with hydrochloric acid and the employer did not provide comprehensive, understandable training annually. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states that employees and their representatives were informed of this abatement.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.151 C
- Issued
- Abate by
- Penalty
- Initial $6620.00 · Current $5000.00 Reduced
General-duty citation text
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use: a) 551 Old Swede Rd, Douglassville, PA 19518 - Leech Room: On or about January 15, 2026, employees were exposed to injurious corrosive materials including, but not limited to, hydrochloric acid and suitable facilities for the quick drenching or flushing of the eyes were not provided. Two, 32 fluid once eyewash bottles were present on the wall in the Leech Room next to a sink, however, the eyewash bottles and sink would not have been capable of delivering a minimum of 1.5 liters per minute (0.4 gallons per minute) of flushing fluids, as described in ANSI Z358.1. b) 551 Old Swede Rd, Douglassville, PA 19518 - Leech Room: On or about January 15, 2026, employees were exposed to injurious corrosive materials including, but not limited to, hydrochloric acid and suitable facilities for the quick drenching or flushing of the body was not provided. Two, 32 fluid once eyewash bottles were present on the wall in the Leech Room next to a sink, however, the eyewash bottles and sink would not have been capable of delivering a minimum of 75.7 liters per minute (20 gallons per minute) of flushing fluids, as described in ANSI Z358.1.
Recent events (2)
- — I (S) $5000
- — Z (S) $6620
1910.1200 F06 II
- Issued
- Penalty
- Initial $5627.00 · Current $5000.00 Reduced
General-duty citation text
29 CFR 1910.1200(f)(6)(ii): Except as provided in 29 CFR 1910.1200(f)(7) and 29 CFR 1910.1200(f)(8), the employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged, or marked with the product identifier and words, pictures, symbols, or combination thereof, which provide at least general information regarding the hazards of the chemicals and which, in conjunction with the other information immediately available to employees under the hazard communication program, would provide employees with the specific information regarding the physical and health hazards of the hazardous chemical: a) 551 Old Swede Rd, Douglassville, PA 19518 - Leech Room: On or about January 15, 2026, the four storage tanks containing hydrochloric acid were not labeled. The tanks did not contain the substance name, signal word, hazard statements, or pictograms. No abatement certification required.
Recent events (2)
- — I (S) $5000
- — Z (S) $5627
1910.132 D02
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.132(d)(2): The employer did not verify, through a written certification, that the required workplace hazard assessment had been performed: a) 551 Old Swede Rd, Douglassville, PA 19518 - Leech Room: On or about January 15, 2026, employees performed tasks involving hydrochloric acid and were required to wear personal protective equipment (PPE), including, but not limited to, face shields, safety glasses, tight-fitting half facepiece respirators, gloves, protective sleeves, and aprons. The employer did not prepare a written workplace PPE hazard assessment that outlined the hazards present which necessitated the use of the PPE. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states that employees and their representatives were informed of this abatement.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at WOLF TECHNOLOGIES, LLC
DOUGLASSVILLE, PA—2026-01-15
WOLF TECHNOLOGIES, LLC
DOUGLASSVILLE, PA—2026-01-15
WOLF TECHNOLOGIES, LLC
View WOLF TECHNOLOGIES, LLC's full OSHA safety record →
More inspections in this industry (NAICS 331512)
MILWAUKIE, OR—2026-06-18
317744514 - PCC STRUCTURALS INC
BAY CITY, MI—2026-06-16
ACRA CAST INC
WATERTOWN, WI—2026-05-29
METALTEK INTERNATIONAL, INC.
GALLATIN, TN—2026-05-14
PRECISION CASTINGS OF TENNESSEE, INC.
DOUGLASSVILLE, PA—2026-01-15
WOLF TECHNOLOGIES, LLC
More inspections in PA
MILTON, PA—2026-07-10
HOMETOWN FOODS CHEF BOYARDEE CO.
SUNBURY, PA—2026-07-10
DEMPSEY UNIFORM & LINEN SUPPLY, INC
LANDISVILLE, PA—2026-07-10
FAIRVIEW DEMOLITION LLC
YORK, PA—2026-07-10
AMERICAN SPECIALTY SYSTEMS INC.
WILLIAMSPORT, PA—2026-07-10
INTERNATIONAL PAINT PROS
Source