1,224,460Inspections Most recent open 2026-07-13 Last loaded 2026-07-16
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Inspection: OMEGA MEDICAL IMAGING, LLC

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of OMEGA MEDICAL IMAGING, LLC in 3400 SAINT JOHNS PARKWAY SUITE 1020, SANFORD, FL 32771 (NAICS 334510). OSHA activity number 348693052.

Watch Omega Medical Imaging, LLC — free Get an email when a new federal OSHA severe-injury report for Omega Medical Imaging, LLC is published. One employer, no account, unsubscribe in one click.
Site address
3400 SAINT JOHNS PARKWAY SUITE 1020
City
SANFORD
State
FL
ZIP
32771
Mailing
3400 SAINT JOHNS PARKWAY SUITE 1020, SANFORD, FL 32771
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
334510
Employees
50
Ownership type
A

2 citations on file for this inspection.

1910.134 C01

Serious Gravity 5 1 instance 4 exposed
Issued
Penalty
Initial $6621.00 · Current $3973.00 Reduced
29 CFR  1910.134(c)(1): The employer did not establish and implement a written respiratory protection program with worksite-specific procedures in any workplace where respirators were necessary to protect the health of the employee or whenever respirators were required by the employer.  a. On or about January 15, 2026, in the painting and welding department: employees were exposed to respiratory hazards, in that, the employer failed to establish and implement a written respiratory protection program with worksite-specific procedures for employees using Draeger - X-plore 5500 Full Face Mask respirators during various operations.
Recent events (2)
  • — I (S) $3972.6
  • — Z (S) $6621

1910.134 F01

Serious Gravity 5 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.134(f)(1): The employer did not ensure that employees using a tight-fitting facepiece respirator pass an appropriate qualitative fit test (QLFT) or quantitative fit test (QNFT) as stated in this paragraph:   a.  On or about January 15, 2026, in the painting and welding department: employees were exposed to respiratory hazards while wearing Draeger - X-plore 5500 Full Face respirator, in that, the employees had not been fit tested to wear a respirator.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348693052.