1,224,460Inspections Most recent open 2026-07-13 Last loaded 2026-07-16
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Inspection: A & C HEATING & COOLING CORPORATION

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of A & C HEATING & COOLING CORPORATION in 3055 W 183RD ST., HOMEWOOD, IL 60430 (NAICS 238220). OSHA activity number 348736273.

Watch A & C Heating & Cooling Corporation — free Get an email when a new federal OSHA severe-injury report for A & C Heating & Cooling Corporation is published. One employer, no account, unsubscribe in one click.
Site address
3055 W 183RD ST.
City
HOMEWOOD
State
IL
ZIP
60430
Mailing
305 HICKORY CT., NORTHBROOK, IL 60062
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Last modified
Data loaded
NAICS code
238220
Employees
2
Ownership type
A

3 citations on file for this inspection.

1926.252 A

Serious Gravity 10 1 instance 2 exposed
Issued
Penalty
Initial $3972.00 · Current $1986.00 Reduced
29 CFR  1926.252(a):An enclosed chute of wood, or equivalent material, was not used where materials were dropped more than 20 feet to points lying outside the exterior walls of the building(s):  a.  On or about February 10, 2026, at the above addressed jobsite, employees performing commercial HVAC upgrade operations were discarding material from the rooftop, dropping material approximately twenty-three (23) feet one (1) inch to the ground with no chute in place, thereby exposing employee(s) to struck-by hazards.
Recent events (2)
  • — I (S) $1986
  • — Z (S) $3972

1926.501 B10

Serious Gravity 10 1 instance 2 exposed
Issued
Penalty
Initial $3972.00 · Current $1986.00 Reduced
29 CFR  1926.501(b)(10): Each employee engaged in roofing HVAC activities on low-slope roofs with unprotected sides and edges 6 feet or more above lower levels, was not protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system.  a. On or about February 10, 2026, at the above addressed jobsite, employees performing commercial HVAC upgrade operations at twenty-three (23) feet one (1) inch above the ground were not protected from falls, thereby exposing employees to fall hazards.
Recent events (2)
  • — I (S) $1986
  • — Z (S) $3972

1926.503 B01

Other-than-serious 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1926.503(b)(1):The employer did not verify compliance with paragraph (a) of this section by preparing a written (training) certification record including the name or other identity of the employee trained, the date(s) of the training, and the signature of the person who conducted the training or the signature of the employer.  a. On or about February 10, 2026, at the above addressed jobsite, employees had been provided fall protection training, however, the employer failed to keep a written certification of record.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348736273.