1,224,460Inspections Most recent open 2026-07-13 Last loaded 2026-07-16
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Inspection: HAUSE LABS LLC

Referral inspection · Health discipline

On , OSHA opened a referral health inspection of HAUSE LABS LLC in 2200 E 76TH AVE UNIT C 300, DENVER, CO 80229 (NAICS 325193). OSHA activity number 348760711.

Establishment
HAUSE LABS LLC
Site address
2200 E 76TH AVE UNIT C 300
City
DENVER
State
CO
ZIP
80229
Mailing
2200 E 76TH AVE, DENVER, CO 80229
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Last modified
Data loaded
NAICS code
325193
Employees
30
Ownership type
A

5 citations on file for this inspection.

1910.106 E02 IV D

Serious Gravity 5 1 instance 30 exposed
Issued
Abate by
Penalty
Initial $6621.00 · Current $3311.00 Reduced

Hazardous substances 1371

29 CFR 1910.106(e)(2)(iv)(d): Flammable liquids were not drawn from or transferred into vessels, containers, or portable tanks within a building only through a closed piping system, from safety cans, by means of a device drawing through the top, or from a container or portable tanks by gravity through an approved self-closing valve:  2200 E 76th Ave Unit C 300 Denver, CO 80229 (immediate use storage area across the hall from the production lab):  On or about March 26, 2026, the employer failed to ensure that employees properly transferred flammable liquids using approved methods. Heptane was pumped from a barrel into a plastic bucket, then subsequently poured from the bucket into a large metal pot. Pouring flammable liquids from plastic containers can potentially expose the vapors to ignition sources such as but not limited to static electricity. This condition exposed employees to fire and explosion hazards.
Recent events (2)
  • — I (S) $3310.5
  • — Z (S) $6621

1910.133 A01

Serious Gravity 1 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $3972.00 · Current $1986.00 Reduced

Hazardous substances 1371

29 CFR 1910.133(a)(1): The employer did not ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation:  2200 E 76th Ave Unit C 300 Denver, CO 80229 (immediate use storage area across the hall from the production lab and production lab):  On or about March 26, 2026, the employer did not ensure that an employee pumping, pouring and transferring heptane for the isomerization process were wearing eye protection which would adequately protect them from chemical splash hazards.
Recent events (2)
  • — I (S) $1986
  • — Z (S) $3972

1910.134 E01

Serious Gravity 1 1 instance 20 exposed
Issued
Abate by
Penalty
Initial $3972.00 · Current $1986.00 Reduced
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace:  2200 E 76th Ave Unit C 300 Denver, CO 80229: On or around March 26, 2026, the employer did not ensure that each employee wearing a tight-fitting respirator was medically evaluated prior to use. Employees were exposed to respiratory hazards while performing laboratory operations using heptane.
Recent events (2)
  • — I (S) $1986
  • — Z (S) $3972

1910.134 F01

Serious Gravity 1 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $3972.00 · Current $0.00 Reduced

Hazardous substances 1371

29 CFR 1910.134(f)(1): The employer did not ensure that employee(s) required to use a tight-fitting facepiece respirator passed the appropriate qualitative fit test (QLFT) or quantitative fit test (QNFT):   2200 E 76th Ave Unit C 300 Denver, CO 80229: On or around March 26, 2026, the employer did not ensure that each employee wearing a tight-fitting respirator had been fit tested prior to use. Employees were exposed to respiratory hazards while wearing tight-fitting respirators while performing laboratory operations using heptane.
Recent events (2)
  • — I (S) $0
  • — Z (S) $3972

1910.1200 F06 II

Serious Gravity 1 2 instances 30 exposed
Issued
Abate by
Penalty
Initial $3972.00 · Current $1986.00 Reduced
29 CFR 1910.1200(f)(6)(ii): Except as provided in 29 CFR 1910.1200(f)(7) and 29 CFR 1910.1200(f)(8), the employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the product identifier and words, pictures, symbols, or combination thereof, which provide at least general information regarding the hazards of the chemicals and which, in conjunction with the other information immediately available to employees under the hazard communication program, would provide employees with the specific information regarding the physical and health hazards of the hazardous chemical:  a)  2200 E 76th Ave Unit C 300 Denver, CO 80229 (spectrometry lab):  On or about March 26, 2026, the employer failed to ensure that employees were protected from health and safety hazards associated with chemicals in that an unknown substance was observed in an unlabeled 1 quart plastic bottle.  b)  2200 E 76th Ave Unit C 300 Denver, CO 80229 (production lab):  On or about March 26, 2026, the employer failed to ensure that employees were protected from health and safety hazards associated with chemicals in that a chemicals stored in plastic 55 gallon barrels had labeling which only indicated the name of the chemical inside.
Recent events (2)
  • — I (S) $1986
  • — Z (S) $3972

View HAUSE LABS LLC's full OSHA safety record →