LINCOLNWOOD, IL —
OSHA Inspection: ADA METAL PRODUCTS, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of ADA METAL PRODUCTS, INC. in 7120 NORTH CAPITOL DRIVE, LINCOLNWOOD, IL 60712 (NAICS 332999). OSHA activity number 348762691.
Where did this inspection happen?
- Establishment
- ADA METAL PRODUCTS, INC.
- Site address
- 7120 NORTH CAPITOL DRIVE
- City
- LINCOLNWOOD
- State
- IL
- ZIP
- 60712
- Mailing
- 7120 NORTH CAPITOL DRIVE, LINCOLNWOOD, IL 60712
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332999
- Employees
- 22
- Ownership type
- A
Citations
7 citations on file for this inspection.
19100147 C04 I
- Issued
- Abate by
- Penalty
- Initial $4965.00 · Current $4965.00
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: (a) Production - On February 23, 2026, the employer failed to develop, document and utilize machine specific procedures to control the potentially hazardous energy for machines, such as but not limited to, mechanical power presses machines. This failure prevented employees from knowing the proper information on how to secure all sources of energy, such as electrical, kinetic, pneumatic, and gravitational energy. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (1)
- — Z (S) $4965
19100147 D
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.147(d): The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6): (a) Production: On February 23, 2026, employees were exposed to machine hazards associated with moving parts and pinch points from the unexpected start-up and energization of mechanical power presses when performing setup operations. The employer did not implement energy control application steps such as but not limited to lockout tagout when performing these tasks [per the 1910.147(d)(2) requirements]. As a result, the remaining applicable energy control elements, involving dissipation machine isolation [(d)(3)], LOTO device application [(d)(4)], dissipation of residual energy [(d)(5)(i)], and verification of isolation [(d)(6)], were not implemented to protect employees from machine servicing hazards. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (1)
- — Z (S) $0
19100217 D09 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.217(d)(9)(i): The employer did not establish a die setting procedure for mechanical power press(es) that would ensure compliance with 29 CFR 1910.217(b)(c)(a): (a) Production - On February 23, 2026, the employer failed to ensure that a die setting procedure was established and utilized when employees were performing die set-up on the mechanical power presses at the facility. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (1)
- — Z (S) $0
19100217 C02 I A
- Issued
- Abate by
- Penalty
- Initial $4965.00 · Current $4965.00
General-duty citation text
29 CFR 1910.217(c)(2)(i)(a): Point of operation guard(s) on mechanical power press(es) did not prevent entry of hands or fingers into the point of operation by reaching through, over, under or around the guard(s) (a) Production - On April 14, 2026, the employer failed to adequately guard all sides on the Walsh #1 mechanical power presses to prevent employees from being able to reach around guards to come into contact with the point of operation. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (1)
- — Z (S) $4965
19100217 D09 IV
- Issued
- Abate by
- Penalty
- Initial $4965.00 · Current $4965.00
General-duty citation text
29 CFR 1910.217(d)(9)(iv): Safety blocks were not used when mechanical power press die(s) were being adjusted or repaired in the press: (a) Production - On February 23, 2026, the employer failed to provide and enforce the use of die blocks for use whenever adjustments or repairs were made in the die areas of mechanical punch presses. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (1)
- — Z (S) $4965
19100178 L06
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.178(l)(6): The employer did not certify that each operator has been trained and evaluated as required by this paragraph (l): (a) Facility Wide - On February 23, 2026, the employer did not certify that each forklift truck operator had been evaluated as required by paragraph (l), with certification records that includes the name of the operator, the date of the training, the date of the evaluation, and the identity of the person(s) performing the evaluation. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (1)
- — Z (O) $0
19100217 E01 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.217(e)(1)(i): A program of periodic and regular inspections of mechanical power press(es) was not established and followed to ensure that all parts, auxiliary equipment and safeguards were in a safe operating condition and adjustment: (a) Production - On February 23, 2026, the employer did not establish a program of monthly and weekly inspections to determine the condition of all parts, auxiliary equipment, clutch/brake mechanisms, anti-repeat features, and single stroke mechanisms on all mechanical power presses. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (1)
- — Z (O) $0
More inspections at ADA METAL PRODUCTS, INC.
LINCONWOOD, IL—1984-09-07
ADA METAL PRODUCTS INC
Chicago, IL—1977-01-12
ADA METAL PRODUCTS INC
View ADA METAL PRODUCTS, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 332999)
SAN ANTONIO, TX—2026-07-10
ED LONG'S METAL WORKS
HUNTINGDON VALLEY, PA—2026-07-09
METAL ALLIANCE, INC.
AITKIN, MN—2026-07-01
111512 - TEEMARK MANUFACTURING INC
SOUTH EL MONTE, CA—2026-06-29
VAGA INDUSTRIES
BIRMINGHAM, AL—2026-06-26
SAMUEL, SON & CO. (USA) INC.
More inspections in IL
DECATUR, IL—2026-07-10
TILLAMOOK ILLINOIS, LLC
NEW LENOX, IL—2026-07-10
A.D GENERAL CONSTRUCTION LLC
LOCKPORT, IL—2026-07-09
ROBERTO GOMEZ DBA ROBERTO GOMEZ
AURORA, IL—2026-07-09
DIEGO BARRON DBA DAB CONTRACTORS
CHICAGO, IL—2026-07-09
BALDI CANDY CO. DBA ARWAY CONFECTIONS, INC.
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348762691.