1,224,460Inspections Most recent open 2026-07-13 Last loaded 2026-07-16
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Inspection: POTLATCHDELTIC CORPORATION

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of POTLATCHDELTIC CORPORATION in 729 HIGHWAY 10 E, OLA, AR 72853 (NAICS 321113). OSHA activity number 348774092.

Watch Potlatchdeltic Corporation — free Get an email when a new federal OSHA severe-injury report for Potlatchdeltic Corporation is published. One employer, no account, unsubscribe in one click.
Site address
729 HIGHWAY 10 E
City
OLA
State
AR
ZIP
72853
Mailing
729 HIGHWAY 10 E, OLA, AR 72853
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Last modified
Data loaded
NAICS code
321113
Employees
135
Ownership type
A

7 citations on file for this inspection.

1910.147 C04 I

Serious Gravity 5 1 instance 6 exposed
Issued
Abate by
Penalty
Initial $8040.00 · Current $5628.00 Reduced
29 CFR  1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:  a) On or about February 22, 2026, in the Kiln 3 area, employees were engaged in servicing and/or maintenance activities such as but not limited to removing and replacing components on the 60MM Burner #1 without utilizing energy control procedures.
Recent events (2)
  • — I (S) $5628
  • — Z (S) $8040

1910.147 D02

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.147(d)(2): The machine or equipment was not turned off or shut down using the procedures established for the machine or equipment:   a) On or about February 22, 2026, in the Kiln 3 area, employees were engaged in servicing and/or maintenance activities such as but not limited to removing and replacing components on the 60MM Burner #1 without the energy control source(s) deenergized by using the lockout tagout procedures.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 C04 II

Serious Gravity 5 4 instances 9 exposed
Issued
Abate by
Penalty
Initial $8040.00 · Current $5628.00 Reduced
29 CFR  1910.147(c)(4)(ii): Procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, 29 CFR 1910.147(c)(4)(ii)(A), (c)(4)(ii)(B), (c)(4)(ii)(C) and (c)(4)(ii)(D):  On or about February 22, 2026, in the Kiln 3 area, employees were engaged in servicing and/or maintenance activities such as but not limited to removing and replacing components on the 60MM Burner #1 using deficient hazardous energy control procedures, in that:   a) The procedures did not have a statement of the intended use of the procedures.  b) The procedures did not have specific steps for shutting down and securing machines.  c) The procedures did not have specific steps for the placement and removal of locks.  d) The procedures did not have specific steps for testing the lockout of machines.
Recent events (2)
  • — I (S) $5628
  • — Z (S) $8040

1910.147 C06 I

Other-than-serious 1 instance 7 exposed
Issued
Abate by
Penalty
Initial $903.00 · Current $632.00 Reduced
29 CFR  1910.147(c)(6)(i):The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed:  a) On or about February 25, 2026, in  in Kiln 3 area, On or about February 22, 2026, in the Kiln 3 area, employees were engaged in servicing and/or maintenance activities such as but not limited to removing and replacing components on the 60MM Burner #1.  Lockout procedures had not been inspected at least annually.
Recent events (2)
  • — I (O) $632.1
  • — Z (O) $903

1910.303 B02

Other-than-serious Gravity 1 1 instance 7 exposed
Issued
Penalty
Initial $4823.00 · Current $3376.00 Reduced
29 CFR  1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:  a) On or about February 25, 2026, in  the Kiln 3 area, employees were performing maintenance work where two extension cords were connected in series to provide power to a battery charger.
Recent events (2)
  • — I (O) $3376.1
  • — Z (S) $4823

1910.305 G01 IV B

Other-than-serious Gravity 1 1 instance 7 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.305(g)(1)(iv)(B): Flexible cords and cables were run through holes in walls, ceilings, or floors:  a) On or about February 25, 2026, in Kiln 3 area MCC room, employees were performing maintenance work where an extension cord was run through a hole in the wall.
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

1910.334 A02 II

Other-than-serious Gravity 1 2 instances 7 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.334(a)(2)(ii):There was a defect or evidence of damage that could have exposed an employee to injury and the defective or damaged item was not removed from service and an employee was using it before repairs and tests necessary to render the equipment safe were made:  On or about February 25, 2026, in  the Kiln 3 area, employees were engaged in servicing and/or maintenance activities, in that: a)  An extension cord's insulation was damaged. b) An extension cord's ground pin was missing.
Recent events (2)
  • — I (O) $0
  • — Z (S) $0