KETCHIKAN, AK —
OSHA Inspection: E.C. PHILLIPS & SON, INC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of E.C. PHILLIPS & SON, INC in 1775 TONGASS AVENUE, KETCHIKAN, AK 99901 (NAICS 311710). OSHA activity number 348815879.
Where did this inspection happen?
- Establishment
- E.C. PHILLIPS & SON, INC
- Site address
- 1775 TONGASS AVENUE
- City
- KETCHIKAN
- State
- AK
- ZIP
- 99901
- Mailing
- PO BOX 7095, KETCHIKAN, AK 99901
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Last modified
- Data loaded
Establishment context
- NAICS code
- 311710
- Employees
- 260
- Ownership type
- A
Citations
1 citation on file for this inspection.
1917.50 C01
- Issued
- Abate by
- Penalty
- Initial $16550 · Current $8275 Reduced
General-duty citation text
29 CFR 1917.50(c)(1): Each crane and derrick was not tested as a unit quadrennially and were not examined annually and certificates of tests and examinations were not made readily available for inspection. (a) On the dock, by door number 3, on or about February 12, 2026, employees were exposed to injury in that the red Thern Hoist (#1) Model #4HBN5M-S2, Serial #4022-119148, had not been subjected to quadrennial testing within the previous 4 years, examined within the past year, and did not have certificates of tests and examinations readily available for inspection. (b) On the dock, by door number 2, on or about February 12, 2026 employees were exposed to injury in that the red Thern Hoist (#2) Model #4HBN5N-S2, Serial #4021-114719, had not been subjected to quadrennial testing within the previous 4 years, examined within the past year, and did not have certificates of tests and examinations readily available for inspection. (c) On the dock, by door number 1, on or about February 12, 2026, employees were exposed to injury in that the red Thern Hoist (#3) Model #4HBN5M-S2, Serial #4023-122088, had not been subjected to quadrennial testing within the previous 4 years, examined within the past year, and did not have certificates of tests and examinations readily available for inspection.
Recent events (2)
- — I (S) $8275
- — Z (S) $16550
More inspections at E.C. PHILLIPS & SON, INC
KETCHIKAN, AK—2025-10-03
E.C. PHILLIPS & SON, INC
KETCHIKAN, AK—2025-02-10
E.C. PHILLIPS & SON, INC
KETCHIKAN, AK—2025-02-10
E.C. PHILLIPS & SON, INC
KETCHIKAN, AK—2025-01-15
E.C. PHILLIPS & SON, INC
KETCHIKAN, AK—2024-01-16 00:00:00
E.C. PHILLIPS & SON, INC
View E.C. PHILLIPS & SON, INC's full OSHA safety record →
More inspections in this industry (NAICS 311710)
UNALASKA, AK—2026-07-07
UNISEA INC
SAN FRANCISCO, CA—2026-06-19
ALL SEAS WHOLESALE, INC
WILMINGTON, CA—2026-04-13
J DELUCA FISH COMPANY INC
IPSWICH, MA—2026-03-26
IPSWICH SHELLFISH CO., INC.
PORTSMOUTH, NH—2026-03-24
HIGH LINER FOODS (USA), INCORPORATED
More inspections in AK
ANCHORAGE, AK—2026-07-10
AK, INC
ANCHORAGE, AK—2026-07-08
ONE STOP SERVICES
, AK—2026-07-08
ANGUS ENTERPRISES
ANCHORAGE, AK—2026-07-08
NORTHERN EXCAVATION & CONSTRUCTION, LLC
UNALASKA, AK—2026-07-07
UNISEA INC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348815879.