942,588Inspections Most recent open 2026-07-09 Last loaded 2026-07-13
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Inspection: PENN STAINLESS PRODUCTS INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of PENN STAINLESS PRODUCTS INC. in 190 KELLY RD., QUAKERTOWN, PA 18951 (NAICS 423510). OSHA activity number 348844036.

Site address
190 KELLY RD.
City
QUAKERTOWN
State
PA
ZIP
18951
Mailing
190 KELLY RD, QUAKERTOWN, PA 18951
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Last modified
Data loaded
NAICS code
423510
Employees
100
Ownership type
A

2 citations on file for this inspection.

19100028 B03 II

Serious Gravity 1 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $5426 · Current $5426
29 CFR  1910.28(b)(3)(ii): Each employee is protected from tripping into or stepping into or through any hole that is less than 4 feet (1.2 m) above a lower level by covers or guardrail systems:  a) 190 Kelly Rd. Quakertown, PA - On or about March 31, 2026, employees used the waterjet table slats as a walking working surface and were not protected from tripping or stepping into holes by a cover.

19100028 B11 II

Serious Gravity 1 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $5426 · Current $5426
29 CFR  1910.28(b)(11)(ii): The employer did not ensure that each flight of stairs having at least 3 treads and at least 4 risers is equipped with stair rail systems and handrails as described in 29 CFR 1910.28 Table D-2-Stairway Handrail Requirements:  a) 190 Kelly Rd. Quakertown, PA - On or about March 31, 2026, the stairs used to access the waterjet table did not have adequate handrails to protect employees from falling.