NAICS311615Event Struck by running powered equipment during maintenance, cleaning, testingSource Butchering machinery
An employee was troubleshooting a thigh deboner on a poultry processing line. As he worked to dislodge a thigh bone caught in the blade mechanism, the machine amputated the first and second digits on his left hand. He was hospitalized.
Amputations involving bone loss Other finger(s) n.e.c.HospitalizedAmputation
NAICS311611Event Caught, entangled in running powered equipment normal operationSource Banding, baling, strapping machinery
An employee was using a box strapping machine to place straps on boxes when his right middle finger was caught in the machine, resulting in an open fracture to the distal phalanx.
NAICS311611Event Struck by running powered equipment during maintenance, cleaning, testingSource Conveyors unspecified
An employee was cleaning equipment. The employee came into contact with a sprocket on a conveyor, which deeply lacerated the employee's upper right arm.
Cuts, lacerations, punctures without injury to internal structures Upper arm(s)Hospitalized
NAICS311313Event Contact with hot objects or substancesSource Liquid foods and beverages
An employee was helping change out socks on hard thin juice filters, part of a beet sugar manufacturing operation. While the filter lid was being removed, juice started leaking down the side of the filter. This suggested that the juice was bypassing the seat on the main shutoff valve. While the main shutoff was being checked, the valve was opened and sprayed hot juice on the employee. The employee suffered burns to the left arm, the left ribcage area, the left side of the back, and the left side of the face. The employee was hospitalized.
Thermal burns degree unspecified Multiple body parts n.e.c.Hospitalized
NAICS311999Event Fall on same level due to slip or tripSource Other constructed surface
An employee was returning to their workstation when they tripped over a customer's child and fell to the concrete floor on their left hip. The employee was hospitalized with a fractured hip.
NAICS311611Event Caught, entangled in running powered equipment normal operationSource Butchering machinery
An employee was operating a hide puller when his hand became caught in the hide puller chain. He sustained shoulder and wrist injuries that required surgery.
Traumatic injuries or exposures unspecified Shoulder(s) and wrist(s)Hospitalized
NAICS311611Event Struck by discharged object or substance Source Steam, vapors nonchemical
An employee was working on a pump. When a cap was opened to prime the pump, pressurized steam was released and burned the left side of the employee's body. The employee was hospitalized.
Thermal burns degree unspecified Part of body unspecifiedHospitalized
NAICS311221Event Contact with hot objects or substancesSource Food products n.e.c.
An employee was bringing a filter online. When the employee opened a valve to initiate flow through the filter, the gasket on the filter housing failed, spraying a water/erythritol mixture (heated to about 175 degrees Fahrenheit) toward the employee. The employee moved back quickly and their chemical suit caught on something, causing it to open. The mixture burned the employee's abdomen and left arm.
Thermal burns degree unspecified Trunk and other upper extremitiesHospitalized
NAICS311813Event Caught, entangled in running powered equipment normal operationSource Food and beverage processing machinery n.e.c.
An employee was filling a hopper that deposited blueberries in muffin trays. Two plastic plates inside the equipment closed, pinching and amputating the employee's left ring fingertip. The equipment was running and unguarded at the time.
Amputations, avulsions, enucleations unspecified Finger or thumb tip(s), nail(s)Amputation
NAICS311611Event Struck by suspended or swinging objects n.e.c.Source Hooks, shackles, magnets, clamshells
An employee was applying spreader hooks to hogs. A hog fell from the hook that he was holding upright and the hook lacerated a tendon in his left hand. The employee was hospitalized for surgery.
Cuts, lacerations, punctures without injury to internal structures Hand(s), finger(s) unspecifiedHospitalized
NAICS311611Event Struck by running powered equipment during maintenance, cleaning, testingSource Butchering machinery
An employee was observing the hide puller from an elevated catwalk to troubleshoot an issue. He was struck in the head by the hide puller and sustained a fractured skull.
NAICS311611Event Struck by running powered equipment during maintenance, cleaning, testingSource Conveyors belt, slot, chain
An employee was unjamming a box coming from a case sealer when their right hand was caught in a conveyor belt. Their middle and ring fingers sustained amputations to the second knuckle.
Amputations involving bone loss Other finger(s) n.e.c.HospitalizedAmputation
NAICS311330Event Multiple types of overexertions, bodily motion and positionSource Boxes, crates, cartons
An employee was performing retails tasks including bending over and lifting 35-pound cases of product. After lifting about 25 boxes he felt back pain, resulting in severe nerve root compression at the base of the spinal cord due to a disc herniation. He required hospitalization and surgery.
Disc disorders, herniated disc Back lumbar regionHospitalized
NAICS311611Event Caught, entangled in running powered equipment normal operationSource Conveyors screw, auger
An employee was cleaning the floor and placing material into the auger system for processing when his protective clothing and foot became entangled in the rotating auger shaft. The employee's leg was crushed, resulting in a laceration and a toe amputation.
Amputations involving bone loss Toes(s), toenail(s)Amputation
NAICS311511Event Inhalation of harmful substance single episode or single shiftSource Carbon monoxide
An employee was operating a propane forklift inside a trailer when they suffered carbon monoxide exposure, resulting in hospitalization for carbon monoxide poisoning.
Poisoning, poisoning-related asphyxia BODY SYSTEMS Hospitalized
NAICS311999Event Struck by running powered equipment during maintenance, cleaning, testingSource Conveyors unspecified
An employee was freeing material from a conveyor when his hand became caught between the conveyor and the guarding. The employee sustained a laceration and fractures to his hand and arm.
Fractures and surface, flesh wounds Hand(s) and arm(s) n.e.c.Hospitalized
NAICS311611Event Struck by running powered equipment during maintenance, cleaning, testingSource Butchering machinery
An employee was operating a machine in the rendering department and noticed a belt was moving slowly. He was working to make the belt go faster when the belt pulled his left hand and the pulley partially amputated his ring fingertip.
Amputations, avulsions, enucleations unspecified Finger or thumb tip(s), nail(s)Amputation
NAICS311812Event Injured by object pushed or pulled by personSource Barrels, drums, cans nonpressurized
An employee was rotating and moving a 55-gallon barrel full of corn syrup. The employee's finger was caught between the barrel and the edges of a bunghole cover, causing a partial amputation to the finger.
Amputations, avulsions, enucleations unspecified Other finger(s) n.e.c.Amputation
NAICS311811Event Injured by object handled by person unspecifiedSource Conveyors unspecified
An employee was helping to move a damaged conveyor. When they were moving it, the leg started to fold in and amputated the tip of his left ring finger.
Amputations, avulsions, enucleations unspecified Finger or thumb tip(s), nail(s)HospitalizedAmputation
NAICS311611Event Nonroadway collision with other vehicle(s) intersecting, turningSource Pallet jack riding
The injured employee was driving a pallet jack. He rounded a corner as another employee on a stand-up reach truck was shifting into reverse to back up. The two vehicles collided and the pallet jack was swept into stationary racking used for storing product, causing the pallet jack driver to become pinned against the racking. The employee was hospitalized with lacerations to their right hand and a perforated bladder and broken pelvis that required surgery.
Multiple severe wounds and internal injuries Multiple trunk locationsHospitalized
NAICS311119Event Struck by running powered equipment n.e.c.Source Machinery unspecified
An employee was collecting a sample from under an auger using a sample tube. The sample tube became clogged with dirt. He tapped it against the auger to dislodge the dirt when the auger contacted his middle finger, resulting in an amputation.
Amputations involving bone loss Other finger(s) n.e.c.HospitalizedAmputation