Contact with hot objects or substances · Traumatic injuries and disorders, unspecified
At a glance
Federal OSHA recorded a severe workplace injury
at POET Biorefining, 1660 Hillman-Ford Road, MARION, OHIO 43302
on — Traumatic injuries and disorders, unspecified, affecting the nonclassifiable.
Watch Poet Biorefining — freeGet an email when a new federal OSHA severe-injury report for Poet Biorefining is published. One employer, no account, unsubscribe in one click.
Final narrative
One employee was hospitalized after a sample port on a sodium hydroxide line failed, showering the employee with sodium hydroxide at 190 degrees Fahrenheit.
HospitalizedNonclassifiableSodium and potassium hydroxide, potassium carbonate
An employee connected a steam line to a hose to clean equipment when the fitting broke loose. They were struck by steam in the left inner thigh, resulting in burns that required hospitalization.
An employee was making tea when she noticed tea grinds were collecting on the side and water was no longer dripping through the funnel. The employee was checking the funnel when boiling water and tea grinds spilled onto the left side of her body. The employee sustained burns to her neck, back, and arm.
An employee had turned off the ball valve on a waterpipe system and was removing the plug when the coupling system attached to the strainer came apart. Hot water sprayed on his arm and back, resulting in first- and second-degree burns that required surgery.
An employee was using a shovel to remove waste vermiculite from molten zinc. The metal had been placed in a bin and partially hardened. The employee broke through the partially hardened metal; still-molten metal flowed to the employee's steel-toed right boot and entered through the cloth boot tongue. The employee suffered a third-degree burn to the right foot and was hospitalized.
More severe injuries in this industry (NAICS 325193)
An employee was backing up a forklift when the frame of the forklift clipped the wall. The employee's right little finger was pinched between the wall and the forklift, resulting in amputation.
An employee was removing contaminants from a low point drain on an ammonia line through a hose and into a container of water. A release of pressure from the end of the hose exposed the employee to anhydrous ammonia, resulting in chemical burns to his face, arm, and chest as well as ammonia inhalation. He was hospitalized.
At about 7:00 a.m. on February 11, 2025, an employee was troubleshooting a system that had failed to start. Suspecting a tripped breaker and intending to test the system's motor leads, he hooked up an insulation resistance tester. The side of the breaker the tester was hooked up to was still energized, resulting in an arc flash. The employee was hospitalized with second-degree burns to his face and right arm.
An employee was preparing hopper rail cars for loading. The employee fell from the platform used to access the rail car lids, landing in an empty hopper and suffering broken ribs.
An employee was working to deliver mail to an apartment building. She was waiting for a customer to move, to obtain clearance to the mailboxes. The door swung inward and closed on her right little finger. The top half of her finger was surgically amputated.
An employee fell from a step ladder while reaching for a tie-off point. He impacted the ground, and landed on his bolt bag which contained tools. The employee was hospitalized with fractured ribs, and a lacerated spleen and kidney.
On October 30, 2025, an employee was working to adjust a stackable metal shipping container. As the container dropped into place, it caught the employee's hands in an area between the upper and lower cross-members. The employee suffered a laceration to the left ring finger that required stitches, bruising to the right ring finger, and fractures to the right middle finger that necessitated medical amputation of the fingertip.
An employee was moving a scissor lift through a doorway. The employee was pinned between the scissor lift and the doorframe, sustained a back injury, and was hospitalized.
An employee was setting up communication equipment for a meeting. They were walking and tripped over a speaker on the ground. The employee sustained a leg injury.