105,313Records 71,083Employers 85,290Hospitalizations 27,770Amputations 2015-01-01 2025-10-31
Safety Incidents OSHA Severe Injury Reports · 2015–2025

Yachiyo Manufacturing of America

Caught in running equipment or machinery during maintenance, cleaning · Amputations

Federal OSHA recorded a severe workplace injury at Yachiyo Manufacturing of America, 565 Beulah Church Rd., CARROLLTON, GEORGIA 30117 on — Amputations, affecting the finger(s), fingernail(s), n.e.c..

While attempting to unclog a dust collection bin's rotary valve, an employee's fingers got caught in the flap wheel of the valve. His three left-hand middle fingers were severed above the second knuckle.

Amputation Finger(s), fingernail(s), n.e.c. Special process machinery, n.e.c.

DGS Import, LLC

An employee was changing a saw blade when the saw machine activated. The employee's left ring and little fingers were amputated.

Millennium Mat Company

An employee was clearing a jam from the label cutting machine when their left middle finger was partially amputated.

Bauer Foundation Corp.

Two employees were repairing the hydraulic engagement pins on a rented front-end wheel loader. The machine controls were activated to move the attachment pins and an employee's finger was caught between the pins and the bushings. Their right index finger was partially amputated.

Guggisberg Cheese, Inc.

An employee was cleaning the conveyor on a piece of equipment when they slipped and their right hand was pulled into the chain sprocket. The employee's fifth fingertip was amputated.

Alsco Inc.

An employee was throwing blankets onto a blanket folding and stacking machine. A blanket got stuck in the machine and she attempted to remove it when the machine contacted her right little finger, resulting in a fingertip amputation.

General Polymeric Corporation

An employee was monitoring a rotary press when his left hand became caught in the machinery. The employee's left middle finger was amputated at the distal interphalangeal joint.

MCM Plastics, Inc.

An employee was sweeping in an area with powdered PVC on the floor and began having difficulty breathing and coughing up blood, The employee was hospitalized for inhalation of PVC.

Lawter Inc.

An employee was working on a pastillator machine, which processes resin-based materials into solid pastilles. His right hand became caught between the feed roller (operating at approximately 350 F) and the cooling belt. The employee s glove and shirt sleeve adhered to his arm due to the heat. The employee sustained third-degree burns to his right hand and forearm, requiring hospitalization and surgery.

AdvanSix, Inc.

An employee was troubleshooting a leak on a low pressure (less than 50 PSI) condensate line in the oxidation area of the plant. He was working to remove insulation around a valve when either the valve or the line failed, and hot condensate contacted his right arm, right abdomen area, and the front of both legs, resulting in second- and third-degree burns.

Rochling Machined Plastics

An employee was replacing a fan on a cooling unit. As he went to adjust a pump, the unit caught his right hand and the fan blades severely lacerated his index finger. He underwent a medical amputation to the finger.

GS II Building Products, Inc.

An employee was helping to lift the grating from a floor draining system when the grating slipped and landed on his hand, resulting in the amputation of his right middle finger at the first joint.

US Battery Manufacturing Company, Inc

A casting machine jammed. An employee's hand was caught in the machine, where a belt line caught and amputated the tip of his finger.

Alfa Insurance

During a workshop meeting in a hotel, an employee heard a drilling noise, so he walked outside to see what it was. An explosion occurred (possible gas line) and his face, ear, and hair were burned. He also fell and sustained a pelvic fracture.

EMORY UNIVERSITY HOSPITAL

An employee slipped on condensation on a walkway in a parking garage. She fell and suffered a closed fracture to the neck of the left femur.

Bull Moose Tube

An employee was using a tool to remove a rag from a roll on the tube mill. The roll pulled the tool and the employee's right hand into the roll, resulting in a partial amputation of the little finger and a fracture to the index finger.