at Turner Industries, 39018 Hwy 3089, DONALDSONVILLE, LOUISIANA 70346
on — Amputations, affecting the fingertip(s).
Final narrative
An employee was helping an aerial access driver load multiple mobile light plants that were off-rent onto an aerial access trailer. The employee was bent down in a squat position, attempting to adjust the tongue of a mobile light tower, when the aerial access driver put his back against the rear light plant and shoved it forward. The employee's index finger was caught between the transport trailer deck and tongue of the mobile light tower, amputating the left index fingertip.
Two employees were replacing cartridge filters at the recycle oil filter in a hydrocracking unit. While removing compression springs from the top of the filters located within the filter pot, vapors that had accumulated within the filter tubes ignited, causing a flash fire. Both employees suffered burns to multiple body parts and were hospitalized.
An employee was inspecting a furnace. While removing an access door from the furnace, the employee's finger was pinched between the access door and the outer furnace beam support, resulting in amputation of the left little fingertip.
Two employees were setting a metal pipe in place for installation on a metal rack. When one employee pushed on the pipe, the other employee's left index fingertip was pinched between the pipe flange and a conduit. The employee's left index fingertip was amputated.
Employees were preparing to unload material with a crane. When the front outriggers were extended it contacted an employee's right foot resulting in a crushing injury and great toe amputation.
An employee was operating a forklift and unloading a truck. After the truck was unloaded, the employee got off the forklift and proceeded to adjust the dock plate with a hook tool. The dock plate slipped and the employee went to adjust the plate with their hand when their left middle finger got caught. Their finger was amputated above the first joint.
An employee was rotating a carbide granulator blade when his finger was caught between the blade and a stationary part of the machine. The employee's right middle finger was partially amputated and they suffered an avulsion to the right ring fingertip.
An employee was using a CNC metal lathe machine in manual mode to check that the thread blocking tool made contact with the jaws. As the employee was manually spinning the spindle, his index fingertip was crushed between the spindle's jaws and the grooving insert, resulting in a fingertip amputation.
During a material handling operation, an employee's fingertip was caught under an air conditioning unit as the unit was lowered onto a cart. The employee's fingertip was amputated.
An employee was removing a bolt from a tractor hub when their right index finger was caught between the hub and the frame. The employee's fingertip was crushed and the employee was hospitalized.
More severe injuries in this industry (NAICS 213112)
An employee had been cleaning the work area. While lifting a saw, the employee's index finger was lacerated by the saw blade. A tendon was cut and required surgery.
An employee was delivering home heating fuel when bees came from the ground and stung the employee's face, neck, torso, and hands. The employee proceeded to shut off the oil flow before losing consciousness. They were hospitalized due to an anaphylactic reaction.
An employee was using a torch to loosen a bolt on a water trailer. Natural gas was present in the water and it ignited, causing a fire. The employee sustained third-degree burns to their upper leg.
An employee had been conducting crane operations. The employee went to stop a piece of oil and gas equipment for tubular running from falling over to the ground. Their right hand was caught between a rolling ladder and the equipment, resulting in fractures to the index and middle fingers. They were hospitalized and the middle finger required surgery.
An employee was working to install a drive belt on a water pump. He was holding the belt on both sides of the pulley, working to route it over the top. As he pulled down with his right hand, the pulley rotated and the belt slid over it, pulling his left little finger between the pulley and the belt. He suffered an amputation to the fingertip as well as a fracture to the ring finger.
A driver was exiting his vehicle outside the plant gate when his foot slipped on the top step of the truck. He fell to the ground, landed on his left hip and elbow. The employee was hospitalized with a fractured hip/femur.
A security employee was responding to an urgent call from staff regarding a violent patient. The employee tripped and fell on the floor outside of the stairwell. The employee sustained a closed head injury, contusion of the cerebrum without loss of consciousness, and a closed fracture of the distal end of the right radius.
A temporary employee was testing an electrical starter motor. He was placing tape on the starter while the breaker was not engaged, but the starter sent an arc flash that burned his hands and stomach.
An employee was walking on a sidewalk and stubbed his toe on an elevated portion of concrete, causing him to trip and fall. The employee's right knee was dislocated.