105,313Records 71,083Employers 85,290Hospitalizations 27,770Amputations 2015-01-01 2025-10-31
Safety Incidents OSHA Severe Injury Reports · 2015–2025

InDyne, Inc.

Bites and stings, unspecified · Puncture wounds, except gunshot wounds

Federal OSHA recorded a severe workplace injury at InDyne, Inc., 516 Perimeter Rd. Suite 1, EGLIN AFB, FLORIDA 32542 on — Puncture wounds, except gunshot wounds, affecting the finger(s), fingernail(s), unspecified.

An employee was going to install concrete forms on the range in the air force base. While he was putting a piece of plastic into the concrete form, his right-hand middle finger was bitten by a snake. He was hospitalized overnight.

Hospitalized Finger(s), fingernail(s), unspecified Reptiles, unspecified

InDyne, Inc

An employee came off a ladder and then fell down the steps, breaking a shoulder and wrist.

InDyne, Inc.

An employee was moving a pole containing a security camera downward to adjust the camera. The top portion of his right middle finger got caught and was amputated between the top and lower portion of the pole's hinge.

View InDyne, Inc.'s full OSHA safety record →

EN Engineering LLC

On October 25, 2023, an employee suffered an insect bite/sting, which caused a swollen arm that required hospitalization.

Usxpress, Inc

An employee was walking around a truck at a weigh station when they suffered a spider bite on their left leg. The employee was hospitalized.

PHOENIX HOME CARE

An employee was in a client's yard when they were bitten by a bug. The employee was hospitalized for treatment.

MPS Egg Farms

An employee was walking through the chicken barn checking the chickens. They were bitten by a spider on the left shoulder and experienced a reaction to the spider bite.

C & W Facility Services Inc.

An employee's hand was caught in a conveyor belt as they worked to clear a jam in a piece of equipment. The employee suffered a dislocation to the right elbow, as well as a broken ulna near the elbow, and was hospitalized.

JANCO FS 3, LLC

An employee was changing AC filters while on a ladder. The employee stepped up to the second-to-last rung when they slipped and fell about 5 feet to the ground. The employee sustained fractures to their scapula and ribs, a collapsed lung, and a back injury.

Navy NAVFAC-NW

An employee was performing restoration activities outside a 45-gallon condensation tank of a boiler system. As they were performing post-maintenance activities after repairing one of the two discharge pumps, one of the discharge valves would not open. The employee closed the intake pump to cool off the system and open the discharge valve. Two employees opened the inlet valve to return the tank to service. After they cracked open the inlet valve, a side wall of the tank blew out, causing the injured employee to suffer steam burns to half their body.

Geo Group

On August 19, 2025, an employee became ill and dehydrated after working outdoors for eight hours, participating in training activities. He was hospitalized.

Naval Facilities Engineering Command Mid Atlantic

An employee was ascending a fixed ladder and struck his head on an overhead object that was approximately 20 feet above ground level. The employee sustained neck injuries and tingling in his fingers. The employee was hospitalized.

DRIFTWOOD NURSERY & LANDSCAPING, INC

An employee was helping a coworker transport a tall palm tree with a mini skid steer. The employee was severely shocked by a high-voltage electrical wire above the ground.

Hobby Lobby Stores, Inc.

An employee was retrieving a Christmas tree from a shelf using a ladder. He missed a step and fell to the concrete floor. He sustained injury to his head and wrist.

Envelope Seal Insulation, Inc

An employee was inspecting a generator whose radiator was leaking. He slipped, and a fan blade in the generator amputated his thumb and index finger.

Sugar Cane Growers Cooperative of Florida

An employee was operating an agricultural tractor during sugarcane harvesting. The employee sustained a lumbar sprain due to vibration or motion from the tractor.

Air-flo/Erwood Heating & Air Conditioning