Caught in running equipment or machinery during regular operation · Amputations
At a glance
Federal OSHA recorded a severe workplace injury
at EXIDE TECHNOLOGIES, 3639 JOY RD., COLUMBUS, GEORGIA 31906
on — Amputations, affecting the fingertip(s).
Final narrative
An employee was punching cases on an assembly line when he noticed a pair of pliers near the chain and sprocket. As he attempted to retrieve the pliers, the chain snagged his glove, pulling his middle finger between the chain and sprocket and amputating his fingertip. The machine was active and unguarded at the time of the incident.
While maintenance employees were evaluating an actuator on top of his work box, the injured employee supplied air to see which direction controlled the valve. When the air released, the injured employee's left index fingertip was amputated by the actuator valve.
An employee was using a hand torch while a second employee was cleaning the floor 2 to 3 feet in front of the hand torch. While the second employee was standing in front of the wall-mounted hand torch array, an internal explosion dislodged the cover, which then struck her in the back of the head. She was hospitalized with a concussion and laceration to the back of the skull.
An employee was sharpening peeler blades when their shirt was caught in the grinding wheel. The employee sustained tendon damage and a crushed right hand.
An employee was preparing to cut lumber on a panel saw when the clamp engaged and caught the employee's left middle finger, resulting in a fingertip amputation.
More severe injuries in this industry (NAICS 335911)
An employee was operating material handling equipment when their right foot was caught between the material handling equipment and a railing. The employee sustained fractures to the big toe and second toe.
An employee was operating a forklift when it collided with another forklift at an intersection. The employee suffered a broken lower right leg from a rack of battery plates on the forks of the other truck.
Four employees were moving a 400-pound flange to the ground when part of the load was released and the injured employee's hand became caught between the flange and the ground. The employee sustained a left middle fingertip amputation.
An employee was recycling material by adding it to a molten lead pot. The employee came in contact with the molten lead and suffered burns to the lower back and shoulder.
An employee was helping to lift the grating from a floor draining system when the grating slipped and landed on his hand, resulting in the amputation of his right middle finger at the first joint.
During a workshop meeting in a hotel, an employee heard a drilling noise, so he walked outside to see what it was. An explosion occurred (possible gas line) and his face, ear, and hair were burned. He also fell and sustained a pelvic fracture.
An employee was using a tool to remove a rag from a roll on the tube mill. The roll pulled the tool and the employee's right hand into the roll, resulting in a partial amputation of the little finger and a fracture to the index finger.