An employee was training a new coworker on cutting PVC pipe when the saw blade amputated the employee's left index finger just below the first knuckle. The saw was guarded at the time.
An employee was working to repair a spray gun when the trigger was activated and the spray gun lacerated the palm of his right hand. He was hospitalized.
An employee was operating a strip saw. As the employee shut off the saw, their right index and middle fingertips were amputated by the blade before it came to a complete stop.
An employee was using a table saw to cut a piece of wood for wall framing. The wood jumped, causing the employee's hand to move toward the saw, amputating their left index finger and causing a laceration on their hand.
An employee was operating a trim saw. While trying to free a jammed board she had just cut, she came into contact with the running saw blade, which amputated her right thumb.
An employee was hooking up bundled tie-downs with a chain. While he was holding a hook, the other hook was unlocked. This caused the employee's hook to slide down and pinch his right index finger between the chain and the shackle. He suffered an amputation to the fingertip (without bone loss), as well as an open fracture.
An employee was preparing to bend a flat bar in a brake press. When the machine was jogged, the stock rotated up and crushed his left middle fingertip against the outer frame of the die. The fingertip was amputated.
An employee was cutting metal with a torch. A piece of metal struck the employee's left foot, causing multiple fractures to metatarsal(s). The employee was hospitalized.
An employee was descending a ladder carrying a bag of trash. He fell, landed on the ground about 10 feet below, and suffered fractures to his right hip and pelvis.
An employee was checking a pole-type transformer tank for leaks. A hydraulic clamping device was lowered onto his right thumb and crushed it against the sharp edge of the bottom of the tank. He suffered a partial transphalangeal amputation to the thumb.
The injured employee was standing behind a table. She jumped out to scare another employee, but tripped and fell on the tile floor, injuring her right ankle/foot. She was hospitalized with a dislocated ankle that required surgery.
An employee was going into a trailer to mark product for shipment and the trailer pulled away from the dock. The employee fell out of the trailer, contacted the dock plate, and then fell to the ground. The employee was hospitalized with a punctured lung, fractured ribs, and contusions.
An employee was hooking up bundled tie-downs with a chain. While he was holding a hook, the other hook was unlocked. This caused the employee's hook to slide down and pinch his right index finger between the chain and the shackle. He suffered an amputation to the fingertip (without bone loss), as well as an open fracture.
An employee was operating a gas tugger to lift metal sheeting. His left hand was pulled into the pulley, which crushed his left thumb, resulting in avulsions and other tissue damage. He was hospitalized and required surgery.