Struck by object falling from vehicle or machinery-other than vehicle part · Fractures and other injuries, n.e.c.
At a glance
Federal OSHA recorded a severe workplace injury
at Nabors Drilling Technologies USA, Inc., Nabors Rig 624, ABBEVILLE, LOUISIANA 70510
on — Fractures and other injuries, n.e.c., affecting the hand(s), except finger(s).
Final narrative
Employees were using an air hoist to lift/move a crossover sub (pipe) on the platform floor. The lifting cap on the air hoist failed and the load fell on an employee's hand, causing a burst wound in his palm and a fracture in the bottom bone of his hand.
An employee was inserting drilling slips in a wellbore. The drill pipe separated, moved within the wellbore, and struck the employee's head. The employee suffered head trauma.
An employee was applying thread protector covers and moving the floor wrench into a stow position so they could lay pipe down. The wrench crushed the employee's hand between the wrench housing and a pipe.
An employee connected a pipe elevator to a drill string. The pipe elevator unlatched while the string was being lifted. The elevator struck the employee causing a fracture and dislocation to their right elbow. The employee was hospitalized.
An employee was removing tubulars from a mousehole but the slips did not release from the tubular until it was raised. When the slips released, they slid down the tubular and struck the employee in the head. The employee sustained a back injury, a head laceration, and a fractured rib.
An employee was climbing the derrick girt to perform work on a cover. As they went to tie off the top drive, the driller came down with the top drive pulling the employee off the girt and onto the top drive. The employee sustained fractures to the pelvis and tailbone.
An employee was transporting an 800-pound die on a cart from the tool room. The employee was pulling the cart when it struck a metal plate on the floor. This caused the cart to tip forward and the die to slide off the cart. The die struck the employee's left foot and their second toe was amputated.
An employee was using a forklift to load pallets of product on a trailer. He exited the forklift to adjust a pallet by hand. The pallet fell on him, resulting in an injury to the left leg.
An employee was lifting a 500-pound steel counterweight off a pallet using a magnetic hold jib crane. The counterweight detached from the crane and the employee sustained a left foot/toe fracture that required surgery.
An employee was using a pipe wrench to turn a 42-foot-long steel pipe on jack stands to weld the bottom portion. The pipe fell off the stands, striking the injured employee on his left shin. The employee sustained a left leg fracture at the shin area as well as a tibia fracture that required surgery.
More severe injuries in this industry (NAICS 213111)
An employee was stepping down off a 6-inch containment platform to finish loading his truck, when his right ankle rolled. The employee sustained a fractured tibia and fibula at the right ankle and required surgery.
A service crew was pulling a pump and motor from a well. After breaking a joint of pipe loose from another joint, an employee grabbed the chain tongs to prevent the pipe from spinning in the well, so the crew could continue taking it apart. The bolt that attaches the chain to the handle of the chain tongs broke, causing the chain to swing around and strike the employee's lower right leg. The chain severely punctured his leg and fractured his tibia.
An employee arrived on location and loaded a blow-out-preventer (BOP) on a 1-ton flatbed truck. While standing on the flatbed securing the the BOP, the employee stepped into a void/hole on the flatbed surface. This caused him to lose balance and fall off the truck bed with his leg still caught in the hole. As a result, he sustained fractures to his left leg.
An employee was rigging up a location. He was using an Allen wrench to free up rotation and start the drawworks engine manually. The engine rotated and his left little finger became caught between the Allen wrench and the engine. The employee sustained an amputation to his little finger and fractures to his wrist.
A driver was exiting his vehicle outside the plant gate when his foot slipped on the top step of the truck. He fell to the ground, landed on his left hip and elbow. The employee was hospitalized with a fractured hip/femur.
A security employee was responding to an urgent call from staff regarding a violent patient. The employee tripped and fell on the floor outside of the stairwell. The employee sustained a closed head injury, contusion of the cerebrum without loss of consciousness, and a closed fracture of the distal end of the right radius.
A temporary employee was testing an electrical starter motor. He was placing tape on the starter while the breaker was not engaged, but the starter sent an arc flash that burned his hands and stomach.
An employee was walking on a sidewalk and stubbed his toe on an elevated portion of concrete, causing him to trip and fall. The employee's right knee was dislocated.