Traffic & Lighting Systems, LLC

Indirect exposure to electricity, greater than 220 volts · Electrical burns, unspecified

Federal OSHA recorded a severe workplace injury at Traffic & Lighting Systems, LLC, NW Expressway between Portland and NW 63rd, OKLAHOMA CITY, OKLAHOMA 73112 on — Electrical burns, unspecified, affecting the hand(s), unspecified.

Employees were guiding a metal light pole from its base to the ground. As the employees were guiding the light pole, the top portion of the light pole came in contact with a 7200v overhead power line. All three employees received burns to their hands and one employee received burns to the upper torso.

Hospitalized Hand(s), unspecified Lamp posts, street lights

Traffic & Lighting Systems, LLC

An employee was moving a signal arm at a toll booth gate when a nylon sling failed, causing the arm to swing down and strike the employee's chest. He fell to the ground and struck his head.

View Traffic & Lighting Systems, LLC's full OSHA safety record →

Lott Brothers Construction Company LTD

A crew was working near an electrical pole. A co-worker was using a front-loader to grade a slope when the loader slid into a guy-wire and became tangled and stuck. The injured employee used a handheld grinder to cut the wire a few feet from the ground. The lower part of the wire fell to the ground, but the upper part of the wire fell toward the pole and contacted an energized part before the end landed in nearby bushes. The employee attempted to shake the bush to free the wire so it could fall back toward the pole. The wire popped up and contacted his hands, resulting in electrical entry burns to both hands and exit burns on both feet.

Quality Service Team, LLC

On November 18, 2023, two employees were using a 2x4 to lift a power line. The boom lift they were operating made contact with power lines and both employees sustained electrical shock injuries.

Jemez Mountains Electric Co-Op, Inc

An employee was part of a crew that was servicing a power line. The employee was in a bucket truck when he contacted the 7,200-volt power line. The electricity entered through one hand and exited the other, causing several electrical burns. The employee was not wearing proper personal protective equipment at the time.

Commonwealth Edison Company

An employee was helping a crew set up a 45-foot pole between two other poles. It was being set up between two energized lines and the pole made contact with the A-phase. The employee was electrocuted and lost consciousness. The electricity also caused an entry wound in their left forearm and an exit wound in their left foot.

CJE Rebar Corp

An employee was handling a 45-foot long rebar for installation on the third floor of a building at a 30-foot elevation. The rebar came into close proximity of a powerline situated 13 feet off the building. The employee sustained electrical burns to his hands from electric discharge, requiring hospitalization.

Smart Building Technologies - A Fidelity Company

An employee was troubleshooting the control setup for a variable air volume box above a ceiling. The employee's hand came into contact with an exposed, energized 277-volt wire that had loosened from its terminal on the box's assembly. He was shocked and fell off a ladder. His left hand passed across the ceiling grid and was lacerated. He also suffered an electrical burn to the right hand and was hospitalized.

Abbott Electric Inc

An employee was moving a scissor lift through a doorway. The employee was pinned between the scissor lift and the doorframe, sustained a back injury, and was hospitalized.

Mintcrest Corp

An employee was standing on an A-frame ladder approximately 6 feet above the floor while he attached a suspended light fixture to the ceiling. The employee lost balance, and fell to the tiled floor below, sustaining blunt force trauma to his head.

Cupertino Electric, Inc.

An employee was inspecting the overhead area of a single-person lift and repositioning the lift through a double doorway. As they were transitioning through the doorway, they were caught between the doorframe and the vertical mast of the lift. The employee was hospitalized with injuries to the nose, left maxillary sinus, left orbital bone, and left jaw, with fractures at the maxillary sinus area.

Swedberg Electric, LLC

The injured employee was performing routine maintenance on a fan belt/pulley. The injured employee and another person were moving the pulley back and forth manually to find a bearing issue. The injured employee's left ring finger got caught between the belt and the pulley wheel, resulting in a soft tissue amputation.

Rae Corporation

An employee was helping to move a 1,300-pound coil on a cart. The steel caster hit a crack in the concrete, the weld holding the caster onto the cart broke, and the coil and cart tipped over onto the employee. He was hospitalized with a laceration on his forehead and a pelvic fracture on his right side.

Meeco Sullivan

An employee was cutting a piece of metal rod with a metal cutting machine. His right middle finger became caught between the rod and the machine's table. The employee's fingertip was partially amputated.

Edward Jones Investments

An employee was working at her desk. She went to stand up and fell to the floor beside the desk. The employee sustained a hip displacement and required surgery.

Burgess Manufacturing of Oklahoma Inc.

An employee was processing wood boards at a chop saw when the saw malfunctioned and the blade cut her left hand and fingers. She was hospitalized and her little finger was surgically amputated.