Inhalation of harmful substance-single episode · Internal injuries to organs and blood vessels of the trunk
At a glance
Federal OSHA recorded a severe workplace injury
at Cytec Solvay Group, 1 Heilman Avenue, WILLOW ISLAND, WEST VIRGINIA 26134
on — Internal injuries to organs and blood vessels of the trunk, affecting the chest, except internal location of diseases or disorders.
Final narrative
On May 8, 2017, at approximately 11:15 a.m., an employee was attempting to unload cyanuric chloride when the material became airborne and covered the employee's respirator mask, obstructing his vision. In an attempt to clear the mask, it was rinsed with water. The cyanuric chloride reacted with the water and became acidic. He removed his mask and suffered eye and skin irritation as well as breathing difficulties. He was later hospitalized for a chemical burn to the lungs.
HospitalizedChest, except internal location of diseases or disordersCyanide and cyanide compounds, n.e.c.
An employee was passing through a building when she suffered an allergic reaction to a cinnamon air freshener. The employee began to feel dizzy and ill, ultimately becoming unresponsive. The employee was hospitalized.
An employee wearing a blasting hood was preparing to blast inside a tank. The line that supplies the hood with breathing air was plugged into an argon line. The employee breathed the argon gas and fell. The employee was hospitalized for argon poisoning.
An employee was preparing a pump for maintenance. When the employee removed a cover, chemicals were released into the air. The employee was exposed to hydrogen sulfide and methyl mercaptan and was hospitalized.
Two employees were lifting a roll of steel poly bar (50 inches and approximately 150 pounds) from ground level to a height of 4 feet at the 66-inch rubber calendar. One employee dropped the roll, resulting in the poly bar contacting the injured employee's right knee. The employee was hospitalized with fractured right patella.
Employees were loading a 295-pound transformer onto a pickup truck using a forklift. The injured employee was acting as the spotter. The transformer hit the tailgate of the pickup truck and the spotter's right hand was struck by the transformer, resulting in amputation of the ring fingertip.
An employee was wearing full PPE while emptying a 55-gallon drum of phosphorus pentoxide and fainted, collapsing and striking their head against the ground. The employee was hospitalized and it is likely that heat caused by wearing full body PPE contributed to fainting.
An employee was troubleshooting a plug in the super-absorbent polymer line. The employee opened an inspection port and their right hand was caught in a rotary valve, resulting in the amputation of four fingers between the knuckle and the first joint.
An employee was conducting a quality control measure by taking a chemical sample for lab analysis. When the employee was opening the sample point, it broke off and crude 2-Ethylhexyl thioglycolate (EHTG) shot out at 265 degrees, and it covered the employee's legs and right arm and splashed the right side of their face. The employee was hospitalized with first- and second-degree burns to their right thigh, lower right knee, inner left thigh, and upper left forearm.
An employee was conducting routine maintenance on a mixer. New lid pins had been installed, and the employee was rotating by hand to ensure they had been installed correctly. The employee's left middle finger was caught between the lid and top of a pin. The momentum from the mixer continued, causing a crushing injury to the finger. The employee underwent a medical amputation from the top knuckle to the tip of the finger.
An employee was climbing down a 15-foot multipurpose ladder. The employee fell about 8 feet, landing on the concrete floor and the ladder itself. The employee suffered several injuries, all on the right side: broken ribs, a broken sternum, a broken temporal bone, broken shoulder, multiple fractures to the cheekbone, and a brain bleed.
An employee was rolling up the landing gear on his trailer when the handle began to unwind and struck his face, fracturing his jaw. The employee was hospitalized and required surgery.