Fall through surface or existing opening, unspecified · Fractures
At a glance
Federal OSHA recorded a severe workplace injury
at Dow Freeport Texas Operations, 2301 N. Brazosport Blvd., FREEPORT, TEXAS 77541
on — Fractures, affecting the foot(feet) and leg(s), n.e.c..
Watch Dow Freeport Texas Operations — freeGet an email when a new federal OSHA severe-injury report for Dow Freeport Texas Operations is published. One employer, no account, unsubscribe in one click.
Final narrative
An employee was ascending a portable ladder/platform system. The employee got to the top of the platform system and fell through the opening that would normally go over the man-hole of a tractor trailer, suffering a fractured heel and tibia.
HospitalizedFoot(feet) and leg(s), n.e.c.Scaffolds-staging, unspecified
An employee was power washing a metal tank from an elevated platform. They fell through a gap between the platform and the tank. The employee landed on the ground and sustained fractures to their ankles and feet.
An employee was installing a metal roof when he stepped on a skylight. The employee fell through the skylight to the ground, resulting in head and shoulder fractures.
An employee was replacing an HVAC unit in a residential home. While he was in the attic space above the garage, the wood he was walking on broke, causing the employee to fall through the sheetrock to the concrete floor below. The employee bumped his head and sustained a shoulder injury as well as a broken ankle.
An employee was putting a tarp on a water tank while standing on a trailer. She lost her footing and fell through the trailer bed, striking the corner of the trailer bed. The employee sustained internal bleeding.
An employee was repairing a sub-floor in a residential house that had water and fire damage. The employee fell through the sub-floor and landed in the basement, resulting in spinal fractures that required hospitalization.
More severe injuries in this industry (NAICS 325110)
An employee was applying pressure to a tank car loaded with caustic soda solution for post-load leak testing. He twisted the valve plug to check it for leaks when it broke free, releasing the caustic soda solution through the opening. The employee suffered chemical burns to both eyes and to his respiratory tract.
Employees were setting up an 8-inch sewer PVC pipe line. An employee was removing/rolling a scrap PVC pipe off the conveyor when their little fingertip was crushed between the end of the PVC pipe and the post for the overhead bus stop guard (fixed guard). The employee was hospitalized and required surgery.
An employee was walking by an equipment battery (tank battery) when a leak occurred around a heater that caused a flash fire. He was wearing flame-resistant clothing and sustained burns to his palms and back.
Two employees were removing a recirculation pump from service at an evaporator. They were disconnecting pump flanges and couplings from the motor when boiling water burst out from the system. Both employees sustained second-degree burns to the chest, stomach, and arms.
On December 9, 2024, an employee was cleaning out a mixtruder. While he was retrieving some residual pieces of silicone left inside, its rotating blades caught the fingers of his right hand resulting in amputation of all four fingers. The thumb was left intact.
After cutting a slab of beef short ribs, an employee turned to grab the pieces he had cut and his right hand contacted the saw blade. The employee sustained an amputation to his right index finger.
An employee was unloading a carpet pad from a truck when they fell from the truck dock to the concrete below, resulting in five fractured ribs and an injury to their left lung.
An employee was walking up a walkway to enter a building through the back entrance when she tripped over the lip of the cement ramp. The employee fell and sustained a fractured right hip.