105,313Records 71,083Employers 85,290Hospitalizations 27,770Amputations 2015-01-01 2025-10-31
Safety Incidents OSHA Severe Injury Reports · 2015–2025

DEVER ELECTRIC, INC.

Fall through surface or existing opening 16 to 20 feet · Fractures

Federal OSHA recorded a severe workplace injury at DEVER ELECTRIC, INC., 2250 State Highway 198, OSCEOLA, ARKANSAS 72370 on — Fractures, affecting the wrist(s).

An employee was removing panels from a pre-existing roof when he fell 20 feet from the center of the roof to the concrete surface below, breaking his left wrist and severely bruising his pelvis.

Hospitalized Wrist(s) Existing roof openings, other than skylights

Lasting Impressions Enterprises, Inc.

On November 16, 2023, at around 3:30 p.m., a subcontracted employee was painting a door jam on a three-story house when he fell 20 feet through an opened elevator shaft to the floor below. The employee sustained fractured vertebrae that required hospitalization.

GNP, Inc. Sheetmetal

Employees were removing and replacing skylights on a metal roof. The injured employee's lanyard became tangled and they fell through the skylight to the ground 16-18 feet below. The employee suffered fractures to the wrist, ribs, and hip.

Perfectly Safe Systems

An employee was requested by a client to string wire on top of an auditorium. He used a boom lift to access a beam and then exited the boom lift to walk on the beam. He then stepped down on a drop ceiling, lost balance, and fell. The drop ceiling caved in and the employee fell 20 feet onto bleachers sustaining injury to his abdominal area and lower left leg. The employee was wearing a harness, but it was not connected to an anchoring point at the time of the fall.

The Scharine Group, Inc.

An employee was installing decking (steel grates) in a new construction steel framed building. The employees were working approximately 22' above the next lower level, which was a concrete ground floor. The decking was pre-cut with the floor opening prior to installation. Shortly after installing the floor opening, the employee fell through the floor opening, approximately 18' onto a section of metal ductwork, resulting in fractures to the skull, ribs, thorax, and lumbar vertebra, as well as an ear laceration.

BakerTriangle - Liberty Hill Office

An employee was taking measurements of an area for drywall when they stepped backward into a partially covered hole in the floor. The employee fell approximately 17 feet to the level below, sustaining a forehead fracture and avulsion, a right shoulder dislocation, a left forearm fracture, left knee tendon and meniscus tears, as well as multiple contusions and abrasions.

Smart Building Technologies - A Fidelity Company

An employee was troubleshooting the control setup for a variable air volume box above a ceiling. The employee's hand came into contact with an exposed, energized 277-volt wire that had loosened from its terminal on the box's assembly. He was shocked and fell off a ladder. His left hand passed across the ceiling grid and was lacerated. He also suffered an electrical burn to the right hand and was hospitalized.

Abbott Electric Inc

An employee was moving a scissor lift through a doorway. The employee was pinned between the scissor lift and the doorframe, sustained a back injury, and was hospitalized.

Mintcrest Corp

An employee was standing on an A-frame ladder approximately 6 feet above the floor while he attached a suspended light fixture to the ceiling. The employee lost balance, and fell to the tiled floor below, sustaining blunt force trauma to his head.

Cupertino Electric, Inc.

An employee was inspecting the overhead area of a single-person lift and repositioning the lift through a double doorway. As they were transitioning through the doorway, they were caught between the doorframe and the vertical mast of the lift. The employee was hospitalized with injuries to the nose, left maxillary sinus, left orbital bone, and left jaw, with fractures at the maxillary sinus area.

Swedberg Electric, LLC

The injured employee was performing routine maintenance on a fan belt/pulley. The injured employee and another person were moving the pulley back and forth manually to find a bearing issue. The injured employee's left ring finger got caught between the belt and the pulley wheel, resulting in a soft tissue amputation.

NATIONAL MILL MAINTENANCE, LLC

An employee was operating an ironworker (steel punching/shearing) machine. A piece of the tooling broke off and struck the employee's neck; a fragment was lodged in his neck. The employee was hospitalized and required surgery.

The Goodyear Tire & Rubber Company

On October 25, 2025, an employee was stringing up a new reel of tire tread on a machine. The employee pulled a 6-inch tail and proceeded to spool up the liner. As the machine was jogged to begin the liner wrapping process, the liner caught the employee's glove and pulled their right arm into the liner, causing a fracture to the arm.

Big River Steel, LLC

An employee was doing a cable change on top of an electric overhead traveling (EOT) crane. They were positioned between the cable drum and the drive shaft. While rotating the cable drum, the employee reached for the new cable that was to be installed. The grease fitting on the drive shaft caught their fall harness and pulled them underneath the drive shaft. The employee was pinned between the drive shaft and two pieces of angle steel, resulting in a fracture to their left hip.

American Tile & Marble Co., Inc

An employee was helping two other employees to push a pallet of tile on a loading dock. He suffered a broken fibula and was hospitalized.

Johnson Industrial Coatings, LLC.

On October 5, 2025, an employee was pulling a pressure washer hose when it it disconnected from the cooker. The employee was struck by jets of high-pressure water, resulting in lacerations to their left thigh requiring surgery. The employee was hospitalized.