An employee was changing mud cups in the hopper cylinders of a concrete pump truck. The cylinders moved and three of the employees fingers were amputated.
An employee was standing on the rig floor next to a polishing unit. His hand was placed on the polishing unit when the pump was lowered, resulting in amputation of their right thumb, ring, and middle fingertips.
An employee was using air to blow out the air wash to the blender and grinder station. As the employee reached to verify that the air wash was clean, the unit pinched and amputated their fingertip.
An employee was retrieving a lost drill pipe with a lifting bail when their left thumb got pinched between the table and handle of the lifting bail while trying to re-thread the pipe to lift it out. The employee suffered an amputation to the left thumb.
An employee was removing a core chuck from a stationary roll when their right ring finger was pinched between the chuck and the roll. The employee's fingertip was amputated.
More severe injuries in this industry (NAICS 811310)
An employee was operating an ironworker (steel punching/shearing) machine. A piece of the tooling broke off and struck the employee's neck; a fragment was lodged in his neck. The employee was hospitalized and required surgery.
An employee was climbing a ladder to inspect a vent in a restaurant dining area. The ladder slid out on the floor and the employee fell approximately 12 feet onto the ladder and the floor. He was hospitalized with a dislocated shoulder and a back injury.
An employee was operating a lift truck when it struck a stationary lift truck. His left thumb was pinched between the two lift trucks, resulting in a partial amputation.
An employee was disassembling a pressurized unit using a driver drill. When the unit was disassembled, it caused a kickback from the tube head, causing the drill to strike the employee's left forearm. They sustained a diaphyseal fracture to their left radius and ulna, which required surgery.
After repairing a piece of industrial equipment, an employee had brake-cleaning liquid on his gloves. A lighter ignited the liquid, and the employee's hands were severely burned.
An employee was working to deliver mail to an apartment building. She was waiting for a customer to move, to obtain clearance to the mailboxes. The door swung inward and closed on her right little finger. The top half of her finger was surgically amputated.
An employee fell from a step ladder while reaching for a tie-off point. He impacted the ground, and landed on his bolt bag which contained tools. The employee was hospitalized with fractured ribs, and a lacerated spleen and kidney.
On October 30, 2025, an employee was working to adjust a stackable metal shipping container. As the container dropped into place, it caught the employee's hands in an area between the upper and lower cross-members. The employee suffered a laceration to the left ring finger that required stitches, bruising to the right ring finger, and fractures to the right middle finger that necessitated medical amputation of the fingertip.
An employee was moving a scissor lift through a doorway. The employee was pinned between the scissor lift and the doorframe, sustained a back injury, and was hospitalized.
An employee was setting up communication equipment for a meeting. They were walking and tripped over a speaker on the ground. The employee sustained a leg injury.