Advantek Waste Management Services LLC

Direct exposure to electricity, unspecified · Electrical burns, unspecified

Federal OSHA recorded a severe workplace injury at Advantek Waste Management Services LLC, 540 FM 2985, KENEDY, TEXAS 78119 on — Electrical burns, unspecified, affecting the face, unspecified.

An employee was working at a shaker table to properly dispose of oil and gas drilling waste when a water pump created an arc flash that burned the employee's face.

Hospitalized Face, unspecified Pumps

Advantek Waste Management Services LLC

An employee was operating a front-end loader to push flowback solids into the solids bay when fumes from a liquid were ignited causing a flash fire and burning the employee's face and the backside of a hand.

Advantek Waste Management Services, LLC

An employee fell approximately 10 feet while setting straps on a storage tank and landed on his feet. He suffered injuries to both feet and a broken right ankle.

View Advantek Waste Management Services LLC's full OSHA safety record →

Bob Woodall Air Care Systems, Inc.

An employee was installing a 15-amp breaker in an electrical panel when a 12-gauge ground wire touched the positive busbar of the panel, resulting in an arc flash. The employee sustained a second-degree burn to their left hand.

Amentum Spaceport LLC

An employee was repairing an HVAC system in the drop tile ceiling of a conference room when they were shocked, causing them to fall from the ladder. The employee sustained burns to their right middle and ring fingers.

Marsh Bellofram Corporation

An employee was replacing a contactor inside an electrical panel attached directly to a press. The press itself was receiving power from another main panel. After replacing the contactor, the employee flipped the switch and an arc flash occurred, burning the employee's elbow, bicep, and neck.

Heart Utilities of Jacksonville, Inc.

An employee was attempting to switch a medium-voltage primary cable and install a 200-amp fuse barrel. The employee contacted the bottom of the switch gear cradle for the fuse barrel, causing an arc blast. The electricity entered the employee s left hand and exited his big toes, resulting in electric shock and burns to the left hand, arm, shoulder, and both feet. The employee was hospitalized.

Duke Energy Florida, LLC

On December 6, 2023, an employee of Duke Energy was working on a single-phase 120-/240-volt parallel service re-tap when a secondary flash occurred in an underground service. The employee suffered a second-degree burn to the face and was hospitalized.

3S Services, LLC

An employee had been cleaning the work area. While lifting a saw, the employee's index finger was lacerated by the saw blade. A tendon was cut and required surgery.

Roby's Propane Gas

An employee was delivering home heating fuel when bees came from the ground and stung the employee's face, neck, torso, and hands. The employee proceeded to shut off the oil flow before losing consciousness. They were hospitalized due to an anaphylactic reaction.

Myers Trucking, Inc.

An employee was using a torch to loosen a bolt on a water trailer. Natural gas was present in the water and it ignited, causing a fire. The employee sustained third-degree burns to their upper leg.

Weatherford U.S., L.P.

An employee had been conducting crane operations. The employee went to stop a piece of oil and gas equipment for tubular running from falling over to the ground. Their right hand was caught between a rolling ladder and the equipment, resulting in fractures to the index and middle fingers. They were hospitalized and the middle finger required surgery.

Helmerich & Payne IDC Inc

An employee was working to install a drive belt on a water pump. He was holding the belt on both sides of the pulley, working to route it over the top. As he pulled down with his right hand, the pulley rotated and the belt slid over it, pulling his left little finger between the pulley and the belt. He suffered an amputation to the fingertip as well as a fracture to the ring finger.

T G Meat Center LLC

After cutting a slab of beef short ribs, an employee turned to grab the pieces he had cut and his right hand contacted the saw blade. The employee sustained an amputation to his right index finger.

Professional Flooring Supply

An employee was unloading a carpet pad from a truck when they fell from the truck dock to the concrete below, resulting in five fractured ribs and an injury to their left lung.

EnviroSafe Demil LLC

An employee was inspecting flares processes. The employee received burns to the front side of the body, face and arm from the flares.

Inteplast Group

An employee was removing plastic material from a production line when the machine cycled and amputated his left index, ring, and little fingers.

Regency IHS of Fairwinds Halletsville, LLC

An employee was walking up a walkway to enter a building through the back entrance when she tripped over the lip of the cement ramp. The employee fell and sustained a fractured right hip.