Caught in running equipment or machinery during regular operation · Amputations
At a glance
Federal OSHA recorded a severe workplace injury
at Muller Cooper Tube Company, Inc., 400 Muller Road, FULTON, MISSISSIPPI 38843
on — Amputations, affecting the finger(s), fingernail(s), n.e.c..
Final narrative
An employee was using a polishing machine to sand down a steel rod when his left hand was caught in the rotating sand paper, amputating his pinky finger at the knuckle.
An employee was sharpening peeler blades when their shirt was caught in the grinding wheel. The employee sustained tendon damage and a crushed right hand.
An employee was preparing to cut lumber on a panel saw when the clamp engaged and caught the employee's left middle finger, resulting in a fingertip amputation.
More severe injuries in this industry (NAICS 331421)
An employee was polishing a bar on the lathe with sandpaper when the bar wrapped around the employee's glove and pulled it off. The employee sustained fractures to their index finger, wrist, and a knuckle.
An employee was using an electrical meter to troubleshoot an electrical drive system. While removing the probe, the employee made contact with the bus and was shocked. The employee sustained burns to their fingers and a dislocated shoulder.
An employee was setting up a furnace and lighting the torch on the furnace when they sustained burns from a flashback flame. The employee was hospitalized with burns to their head, face, chest, arms, and armpit area.
An employee was using a metal bar tied to a nylon strap attached to a jib crane to tighten a metal ring on a heated extrusion press. The metal bar flew off and struck the employee in the left forearm, fracturing it.
An employee was troubleshooting the lift table of the automated take-up mechanism on the jacket extrusion line. He was able to get the table to raise up, at which point it engaged and lowered. The employee's leg was pinned between the lift table and the concrete floor. His ankle was broken and he was hospitalized, requiring surgery.
An employee was checking a pole-type transformer tank for leaks. A hydraulic clamping device was lowered onto his right thumb and crushed it against the sharp edge of the bottom of the tank. He suffered a partial transphalangeal amputation to the thumb.
The injured employee was standing behind a table. She jumped out to scare another employee, but tripped and fell on the tile floor, injuring her right ankle/foot. She was hospitalized with a dislocated ankle that required surgery.
An employee was going into a trailer to mark product for shipment and the trailer pulled away from the dock. The employee fell out of the trailer, contacted the dock plate, and then fell to the ground. The employee was hospitalized with a punctured lung, fractured ribs, and contusions.
An employee was hooking up bundled tie-downs with a chain. While he was holding a hook, the other hook was unlocked. This caused the employee's hook to slide down and pinch his right index finger between the chain and the shackle. He suffered an amputation to the fingertip (without bone loss), as well as an open fracture.
An employee was operating a gas tugger to lift metal sheeting. His left hand was pulled into the pulley, which crushed his left thumb, resulting in avulsions and other tissue damage. He was hospitalized and required surgery.