Exposure through intact skin, eyes, or other exposed tissue · Chemical burns and corrosions, unspecified
At a glance
Federal OSHA recorded a severe workplace injury
at Environmental Test Boring, P.O Box 70043, BUTLER, NEW JERSEY 07405
on — Chemical burns and corrosions, unspecified, affecting the face, unspecified.
Watch Environmental Test Boring — freeGet an email when a new federal OSHA severe-injury report for Environmental Test Boring is published. One employer, no account, unsubscribe in one click.
Final narrative
An employee was injecting fluids into a well. As he disconnected the hose, caustic solution sprayed his face.
HospitalizedFace, unspecifiedChemicals and chemical products, unspecified
On November 27, 2023, an employee was emptying a 2-inch product line that transports sodium hydroxide liquid from a rail car to a 275-gallon tote tank. The nozzle came out of the tote and sprayed sodium hydroxide onto the employee's face. The employee was hospitalized with chemical burns to their face, mouth, and neck.
An employee was working with sulfuric acid as part of the production process. While transferring the chemical from a large container to a smaller container, it splashed on his body and hand, resulting in a chemical burn.
An employee knelt in wet concrete while performing work as a concrete finisher and sustained a chemical burn to the right shin. The employee was hospitalized and required surgery.
An employee was using a 5-gallon bucket to unload acid product from a tank. Residual product leaked into the containment area, causing the employee to sustain first- and second-degree burns to the chest, as well as third-degree burns to the arms.
An employee was transferring an alkaline cleaning chemical from a bulk container into 1-gallon containers. The employee lifted a gallon container by its label tag. The tag broke causing the container to fall approximately 14-18 inches. The container struck the ground and the contents splashed onto the employee causing chemical burns to their eyes.
More severe injuries in this industry (NAICS 237110)
An employee was moving a tensile strength test device with a dolly. The device fell from the dolly onto the employee's right leg, causing a compound fracture.
On October 7, 2025, employees were conducting trenching operations for the installation of a new sewer line system. The excavator's bucket was detached and put inside the trench as it was being exchanged for a different-sized bucket. An employee entered the trench with a shovel to move some dirt located at the front end of the pipe. The excavator bucket shifted and slid, striking the employee s right foot and trapping it against the ground. The employee sustained a fractured right tibia.
Employees were working to dislodge a large truck that was stuck in a rut using tow straps and a front-end loader with the bucket removed. An employee connected the straps to the loader and truck and another employee slowly engaged the loader to close the coupler. The injured employee's arm became caught in a pinch point. The employee was hospitalized with a fractured arm.
An employee was lifting a piece of 30-inch line stopping equipment using a jack screw. A lifting eye weld snapped and the load dropped. The end of the jack screw then landed on the employee's heel and crushed it. The employee was hospitalized.
An employee was installing fence posts when they stepped into a recently dug hole that was not visible due to rainfall. The employee's leg was fractured.
An employee assisted in cleaning material from a conveyor pit. After the pit was cleaned, the employee proceeded to replace metal safety plates to ensure other employees did not fall into the pit. While replacing one of the last plates, the employee mis-stepped and fell approximately 5 feet into the pit. The employee was hospitalized with back/side bruising, elbow bruising, bone bruises, and/or fractured ribs.
An employee was walking on the sidewalk. When they stepped off the curb, they fell to the ground, resulting in fractures to their tibia, fibula, and a metatarsal.