Struck by discharged object or substance · Cuts, lacerations
At a glance
Federal OSHA recorded a severe workplace injury
at Bison Specialty Services , 9981 US-90, BEAUMONT, TEXAS 77713
on — Cuts, lacerations, affecting the hand(s), unspecified.
Final narrative
An employee was inspecting his equipment to make sure all safety equipment was in place and properly operating. He was moving a flex lance to another tube when the dump valve was engaged. High-pressure water from the flex lance tip released and cut his left hand.
An employee was hydroblasting when the sprinkler head malfunctioned. Water shot out of the hose at 18,000 psi, blowing off a piece of pipe and tubing. The piece impaled an employee's left leg, breaking the tibia.
An employee was installing wood trim surrounding a skylight inside a home. While holding a piece of trim in it's desired location, his pneumatic nail gun discharged, sending a 3/4-inch pin nail into his left forearm.
An employee removed a safety valve on a trailer that unknowingly contained nitrogen gas. The gas released from the trailer and pushed the employee backward off a scaffold approximately 10 feet before they struck a garage door, resulting in a pelvic injury.
An employee was sitting at her workstation when a nail gun malfunctioned and shot a nail into her left leg. She suffered a puncture and blood vessel injury and was hospitalized.
On November 25, 2023, an employee was using a high-pressured water hose to perform sewer line cleaning operations. The employee's right little finger and palm were lacerated by pressurized water from the hose.
An employee was operating an ironworker (steel punching/shearing) machine. A piece of the tooling broke off and struck the employee's neck; a fragment was lodged in his neck. The employee was hospitalized and required surgery.
An employee was climbing a ladder to inspect a vent in a restaurant dining area. The ladder slid out on the floor and the employee fell approximately 12 feet onto the ladder and the floor. He was hospitalized with a dislocated shoulder and a back injury.
An employee was operating a lift truck when it struck a stationary lift truck. His left thumb was pinched between the two lift trucks, resulting in a partial amputation.
An employee was disassembling a pressurized unit using a driver drill. When the unit was disassembled, it caused a kickback from the tube head, causing the drill to strike the employee's left forearm. They sustained a diaphyseal fracture to their left radius and ulna, which required surgery.
After repairing a piece of industrial equipment, an employee had brake-cleaning liquid on his gloves. A lighter ignited the liquid, and the employee's hands were severely burned.
After cutting a slab of beef short ribs, an employee turned to grab the pieces he had cut and his right hand contacted the saw blade. The employee sustained an amputation to his right index finger.
An employee was unloading a carpet pad from a truck when they fell from the truck dock to the concrete below, resulting in five fractured ribs and an injury to their left lung.