105,313Records 71,083Employers 85,290Hospitalizations 27,770Amputations 2015-01-01 2025-10-31
Safety Incidents OSHA Severe Injury Reports · 2015–2025

Dailey Electric, Inc.

Overexertion in lifting-single episode · Soreness, pain, hurt-nonspecified injury

Federal OSHA recorded a severe workplace injury at Dailey Electric, Inc., 7008 South Rice Ave., BELLAIRE, TEXAS 77401 on — Soreness, pain, hurt-nonspecified injury, affecting the back, including spine, spinal cord, unspecified.

An employee was lifting a hydraulic driller (coring machine) from the ground when he injured his back, requiring hospitalization.

Hospitalized Back, including spine, spinal cord, unspecified Drilling machines, drilling augers

Koch Foods of Cincinnati, LLC

An employee was lifting a motor and reaching to place it on a machine when they sustained a back injury. The employee was hospitalized.

MERCY HOSPITAL

On 12/22/2023, an employee was carrying bins filled with pasta to a refrigerator. As he lifted a 20-pound bin, he felt pain in his lower back. The employee sustained a herniated disc.

Jefferson Lansdale Hospital

An employee was lifting a patient when they pulled a back muscle. She suffered back pain and spasms radiating into her leg with weakness and numbness. The employee's L3-L4 disc was herniated and she was hospitalized.

Raytheon Company

An employee was lifting boxes when they suffered a strained back, resulting in hospitalization.

FUSE BUILDS LLC

An employee was lifting a bundle of insulation with a colleague when he felt severe pain in the right side of his lower back/hip region. The employee sustained a severe muscle injury.

Smart Building Technologies - A Fidelity Company

An employee was troubleshooting the control setup for a variable air volume box above a ceiling. The employee's hand came into contact with an exposed, energized 277-volt wire that had loosened from its terminal on the box's assembly. He was shocked and fell off a ladder. His left hand passed across the ceiling grid and was lacerated. He also suffered an electrical burn to the right hand and was hospitalized.

Abbott Electric Inc

An employee was moving a scissor lift through a doorway. The employee was pinned between the scissor lift and the doorframe, sustained a back injury, and was hospitalized.

Mintcrest Corp

An employee was standing on an A-frame ladder approximately 6 feet above the floor while he attached a suspended light fixture to the ceiling. The employee lost balance, and fell to the tiled floor below, sustaining blunt force trauma to his head.

Cupertino Electric, Inc.

An employee was inspecting the overhead area of a single-person lift and repositioning the lift through a double doorway. As they were transitioning through the doorway, they were caught between the doorframe and the vertical mast of the lift. The employee was hospitalized with injuries to the nose, left maxillary sinus, left orbital bone, and left jaw, with fractures at the maxillary sinus area.

Swedberg Electric, LLC

The injured employee was performing routine maintenance on a fan belt/pulley. The injured employee and another person were moving the pulley back and forth manually to find a bearing issue. The injured employee's left ring finger got caught between the belt and the pulley wheel, resulting in a soft tissue amputation.

T G Meat Center LLC

After cutting a slab of beef short ribs, an employee turned to grab the pieces he had cut and his right hand contacted the saw blade. The employee sustained an amputation to his right index finger.

Professional Flooring Supply

An employee was unloading a carpet pad from a truck when they fell from the truck dock to the concrete below, resulting in five fractured ribs and an injury to their left lung.

EnviroSafe Demil LLC

An employee was inspecting flares processes. The employee received burns to the front side of the body, face and arm from the flares.

Inteplast Group

An employee was removing plastic material from a production line when the machine cycled and amputated his left index, ring, and little fingers.

Regency IHS of Fairwinds Halletsville, LLC

An employee was walking up a walkway to enter a building through the back entrance when she tripped over the lip of the cement ramp. The employee fell and sustained a fractured right hip.