Exposure to environmental heat · Effects of heat and light, unspecified
At a glance
Federal OSHA recorded a severe workplace injury
at United Rentals, Inc., 1723 Athens Road, CRAWFORD, GEORGIA 30630
on — Effects of heat and light, unspecified, affecting the bODY SYSTEMS.
Final narrative
After working on equipment at a customer site, an employee left work feeling ill and was hospitalized for heat-related illness.
Mulching equipment was being used to clear tall vegetation at a job site when the equipment encountered hidden wire in the brush. The wire entered the equipment and was projected out of it approximately 300 feet, striking the injured employee's left leg and resulting in an injury.
An employee was tightening cargo straps to secure a load when he slipped and fell backward to the ground. The employee sustained fractures to the clavicle and ribs and was hospitalized.
An employee was performing finishing work on a residential driveway when they began to experience body cramps and were hospitalized for heat stress and dehydration.
An agent was participating in SWAT team selection and was performing various physical fitness skills including running and exercise intervals. The agent experienced dehydration and a muscular injury that required hospitalization.
On September 26, 2023, an employee was delivering packages when he began to feel ill with a pain in his side. He was hospitalized for heat exhaustion and dehydration.
More severe injuries in this industry (NAICS 811310)
An employee was operating an ironworker (steel punching/shearing) machine. A piece of the tooling broke off and struck the employee's neck; a fragment was lodged in his neck. The employee was hospitalized and required surgery.
An employee was climbing a ladder to inspect a vent in a restaurant dining area. The ladder slid out on the floor and the employee fell approximately 12 feet onto the ladder and the floor. He was hospitalized with a dislocated shoulder and a back injury.
An employee was operating a lift truck when it struck a stationary lift truck. His left thumb was pinched between the two lift trucks, resulting in a partial amputation.
An employee was disassembling a pressurized unit using a driver drill. When the unit was disassembled, it caused a kickback from the tube head, causing the drill to strike the employee's left forearm. They sustained a diaphyseal fracture to their left radius and ulna, which required surgery.
After repairing a piece of industrial equipment, an employee had brake-cleaning liquid on his gloves. A lighter ignited the liquid, and the employee's hands were severely burned.
An employee was helping to lift the grating from a floor draining system when the grating slipped and landed on his hand, resulting in the amputation of his right middle finger at the first joint.
During a workshop meeting in a hotel, an employee heard a drilling noise, so he walked outside to see what it was. An explosion occurred (possible gas line) and his face, ear, and hair were burned. He also fell and sustained a pelvic fracture.
An employee was using a tool to remove a rag from a roll on the tube mill. The roll pulled the tool and the employee's right hand into the roll, resulting in a partial amputation of the little finger and a fracture to the index finger.