105,313Records 71,083Employers 85,290Hospitalizations 27,770Amputations 2015-01-01 2025-10-31
Safety Incidents OSHA Severe Injury Reports · 2015–2025

Impact Alliance, LLC

Caught in running equipment or machinery during maintenance, cleaning · Amputations

Federal OSHA recorded a severe workplace injury at Impact Alliance, LLC, 210 Curie Drive, ALPHARETTA, GEORGIA 30005 on — Amputations, affecting the fingertip(s).

An employee was watching a second employee assess a noise from a cut-off saw. The first employee grabbed the blade because he thought it looked loose. At the same time, the second employee "bumped" the saw, which caused the blade to grab the first employees right index finger and amputate the tip. The saw was not de-energized at the time of the incident.

Amputation Fingertip(s) Sawing machinery-stationary, n.e.c.

DGS Import, LLC

An employee was changing a saw blade when the saw machine activated. The employee's left ring and little fingers were amputated.

Millennium Mat Company

An employee was clearing a jam from the label cutting machine when their left middle finger was partially amputated.

Bauer Foundation Corp.

Two employees were repairing the hydraulic engagement pins on a rented front-end wheel loader. The machine controls were activated to move the attachment pins and an employee's finger was caught between the pins and the bushings. Their right index finger was partially amputated.

Guggisberg Cheese, Inc.

An employee was cleaning the conveyor on a piece of equipment when they slipped and their right hand was pulled into the chain sprocket. The employee's fifth fingertip was amputated.

Alsco Inc.

An employee was throwing blankets onto a blanket folding and stacking machine. A blanket got stuck in the machine and she attempted to remove it when the machine contacted her right little finger, resulting in a fingertip amputation.

CONTAINER GRAPHICS CORP

An employee was using a box cutter when it cut the tip of his left thumb resulting in a fingertip amputation.

PHB Inc.

An employee was inspecting and packing parts when a machine in the area had a die malfunction. This die controls the flow of molten metal. Once it malfunctioned, the molten metal bled into the water line and started spraying into the area where the employee was located. The employee was hospitalized to treat burns to her arm, chest, and mouth.

Mid-South/Central Extrusion Die Co., Inc.

An employee was loading components into fixtures on an automated CNC Line. He was moving a J-Hook lifting apparatus by hand from its storage location to the raw material area in order to pick up a piece of steel. The employee had the crane remote and the neck of the J-Hook apparatus in his right hand. When he went to set the J-Hook down on the floor, he placed his left middle finger inside of the lifting loop of the magnet. As he manually lowered the J-Hook to the floor by the neck, it fell. As the neck dropped to the floor, the magnet shifted and the lifting loop of the magnet retracted into the bracket of the J-Hook, fracturing and amputating the fingertip.

C. L. Tool & Die

An employee was operating a two-handed punch press. When the foot pedal was actuated, the machine cycled and came down onto his left hand causing severe lacerations to the index, middle, and ring fingers to the bone.

ROTO-DIE COMPANY, INC.

An employee was cutting material on a band saw and amputated his left ring fingertip.

GS II Building Products, Inc.

An employee was helping to lift the grating from a floor draining system when the grating slipped and landed on his hand, resulting in the amputation of his right middle finger at the first joint.

US Battery Manufacturing Company, Inc

A casting machine jammed. An employee's hand was caught in the machine, where a belt line caught and amputated the tip of his finger.

Alfa Insurance

During a workshop meeting in a hotel, an employee heard a drilling noise, so he walked outside to see what it was. An explosion occurred (possible gas line) and his face, ear, and hair were burned. He also fell and sustained a pelvic fracture.

EMORY UNIVERSITY HOSPITAL

An employee slipped on condensation on a walkway in a parking garage. She fell and suffered a closed fracture to the neck of the left femur.

Bull Moose Tube

An employee was using a tool to remove a rag from a roll on the tube mill. The roll pulled the tool and the employee's right hand into the roll, resulting in a partial amputation of the little finger and a fracture to the index finger.