Federal OSHA recorded a severe workplace injury
at MMR Constructors, Inc., 1897 Allan Road, MACON, GEORGIA 31201
on — Fractures, affecting the thigh(s).
Watch MMR Constructors, Inc. — freeGet an email when a new federal OSHA severe-injury report for MMR Constructors, Inc. is published. One employer, no account, unsubscribe in one click.
Final narrative
An employee was carrying a tent with three other employees when he stepped in a grassy area and fell, fracturing his right femur.
An employee was dismounting a step ladder when their foot missed the first rung and they fell to the ground, fracturing their right hip and required surgery.
An employee was walking on a ceiling grid and fell approximately 60 feet through a draft opening striking another employee on a lower level. The employee on the lower level was hospitalized for fractures and other injuries. The employee that fell suffered injuries that resulted in a fatality.
An employee removed a high voltage cabinet and went to push a cable through when an arc flash occurred. The employee sustained burns on the right hand, left arm, and the back.
While descending a portable step ladder to reposition it, an employee missed the bottom rung and fell approximately 18 to 24 inches to the concrete floor below. The employee was hospitalized with a fractured right forearm, elbow, and pelvis.
An employee was walking behind the store with another associate to get paperwork from the delivery driver when she fell on the walkway and sustained a leg fracture that required surgery.
An employee was adjusting the forks on a forklift when a fork detached from the forklift. The employee jumped out of the way but fell on the concrete floor. The employee was hospitalized with a broken hip.
An employee was performing maintenance and replacing a seal under a plexiglass viewing cylinder in a pre-expander machine. As the employee was testing the machine before putting it back into service, the viewing cylinder exploded and the employee sustained lacerations to their chest, face, right arm and hand.
Two employees were replacing a compressor and were moving it when one employee dropped the compressor and it landed on his right hand on the floor. The employee sustained an amputation to his middle fingertip.
An employee was pulling a cover off a piece of electrical equipment when a flash occurred and they were electrocuted and sustained burns to their face and both hands.
An employee was helping to lift the grating from a floor draining system when the grating slipped and landed on his hand, resulting in the amputation of his right middle finger at the first joint.
During a workshop meeting in a hotel, an employee heard a drilling noise, so he walked outside to see what it was. An explosion occurred (possible gas line) and his face, ear, and hair were burned. He also fell and sustained a pelvic fracture.
An employee was using a tool to remove a rag from a roll on the tube mill. The roll pulled the tool and the employee's right hand into the roll, resulting in a partial amputation of the little finger and a fracture to the index finger.