Caught in running equipment or machinery, unspecified · Fractures
At a glance
Federal OSHA recorded a severe workplace injury
at Qualex Manufacturing, LLC, 221 Sunset Blvd. , CHAMBERSBURG, PENNSYLVANIA 17202
on — Fractures, affecting the finger(s), fingernail(s), unspecified.
Final narrative
An employee was changing the tooling on a press brake when the machine was activated via the foot pedal. This caused the machine die to crush and break his left middle and index fingers. He was hospitalized and had surgery.
An employee was opening a valve to allow gas to empty into a manifold system when the line blew off. The employee was struck by the barbed hose from a tank, resulting in a laceration on the left side of the head between the left eye and ear as well as a neck fracture.
On December 19, 2023, an employee was setting up a copper wire drawing machine when his left ring finger was pinched between a copper wire and a machine part. The employee's finger was partially amputated.
An employee was checking the gusset seal on a machine. He moved to the next cross sealer and the machine activated, causing an amputation to a left-hand finger. The employee was hospitalized.
An employee was evaluating a coiling machine to verify that the blade was present inside it. The machine's weld function was activated, and the machine crushed the employee's fingers, resulting in the amputation of the left middle and ring fingers.
An employee was driving a forklift when its right front wheel dropped off a 6-inch curb. The forklift rolled over and trapped him against the concrete surface. He suffered a broken pelvis, ribs, and collarbone, as well as a collapsed lung.
An employee was operating a brake press when the top die broke, causing the bottom die to roll out and onto the employee's legs. Both of the employee's legs were crushed below the knee, and both legs were partially amputated. The employee's left leg was also fractured above the knee.
An employee was performing routine maintenance on a shear machine when the machine's foot pedal was engaged and the blade contacted his right middle finger, resulting in a partial amputation.
An employee was helping to tighten down a metal packaging band for shipping. The metal band broke and struck the employee across their face, cutting their left face/eye area. The employee was hospitalized.
An employee was walking into the motor control center (MCC) room when his right ring finger was caught in the hinge of a doorway. He sustained an open phalanx fracture, which resulted in a partial amputation above the first knuckle.
An employee was changing the spacing on a telehandler's forks. A fork slipped, and the employee's left index finger was caught between it and the mast. The fingertip was medically amputated at the first knuckle.
An employee was pulling down a broken skid with a forklift. When the employee backed up the forklift to get the forks out of the skid he pulled down, he contacted the forks of another parked forklift, fracturing both of his legs. He was hospitalized.
An employee was carrying cups back to the kitchen when her foot got caught on a cart and she fell face-first. During the fall, a piece of glass from a cup cut the inside of her mouth, severing an artery. She also sustained a laceration on her lower lip. The employee was hospitalized.