105,313Records 71,083Employers 85,290Hospitalizations 27,770Amputations 2015-01-01 2025-10-31
Safety Incidents OSHA Severe Injury Reports · 2015–2025

Charter Communications, LLC

Other fall to lower level 16 to 20 feet · Fractures

Federal OSHA recorded a severe workplace injury at Charter Communications, LLC, 1042 Proprietors Road, WORTHINGTON, OHIO 43085 on — Fractures, affecting the multiple body parts, n.e.c..

A cable installer at a residential single family home hooked his ladder over a metal strand line, climbed up the ladder and hooked up his fall protection to the strand line and began diagnostics on the communications line. A splice on the strand line failed resulting in the ladder and the employee falling 18 feet to the concrete driveway below. The employee sustained fractures to the elbow and pelvis.

Hospitalized Multiple body parts, n.e.c. Movable ladders, unspecified

Charter Communications, LLC

An employee was working from an extension ladder in a back yard, disconnecting an aerial telecommunications cable line from a house. The employee fell backward from the ladder to the grass below, suffering fractured vertebrae in their back.

Charter Communications LLC.

An employee was removing a service drop at a residential location while on a 28-ft. extension ladder. While ascending or descending the ladder, the employee fell to the ground. The employee was hospitalized with head and back injuries.

Charter Communications, LLC

An employee was descending a ladder that was positioned against a gutter. The ladder slid on the gutter and the employee fell onto concrete pavers about 10 feet below, landing on and breaking their arm.

Charter Communications, LLC

An employee fell from an extension ladder onto an asphalt pavement about 15 feet below, suffering a skull fracture, internal bleeding in the head, a broken collarbone, broken vertebrae, five to eight broken ribs, and a liver laceration. The employee was hospitalized.

Charter Communications LLC

An employee was preparing to leave a job site and was picking up traffic cones when he slipped on black ice and fell to the ground, resulting in a broken ankle.

View Charter Communications, LLC's full OSHA safety record →

P&C Roofing, Inc.

An employee was transitioning from a ladder onto a roof when the ladder slipped and they fell approximately 20 feet to the ground. The employee was hospitalized with fractures to their pelvis and heel.

Melvin Sipaque

An employee was tearing down shingles when they fell approximately 18 feet from a roof to the ground, sustaining a broken ankle.

All Seasons Roofing & Construction Inc

An employee was climbing a ladder to bring material onto a roof. The ladder slid and the employee fell 16 feet to the ground, resulting in a broken knee.

Caterpillar, Inc.

An employee was performing an inspection of a bridge crane while working from a 19-foot scissor lift. The employee was going to use a pendant to move the crane to access a different portion of the crane for visual inspection. The scissor lift guard rails were below the girder of the crane to avoid contact. The tow arm for the crane collectors contacted the guardrail of the scissor lift and caused it to tip over. The employee stayed inside the scissor lift basket as he fell to the floor. The employee sustained fractures to the right arm and hip.

Advantage Solutions

An employee was on a forklift that was elevated approximately 20 feet and was auditing inventory. The forklift malfunctioned and the employee fell down to the surface below, causing them to sustain multiple fractures.

Smart Building Technologies - A Fidelity Company

An employee was troubleshooting the control setup for a variable air volume box above a ceiling. The employee's hand came into contact with an exposed, energized 277-volt wire that had loosened from its terminal on the box's assembly. He was shocked and fell off a ladder. His left hand passed across the ceiling grid and was lacerated. He also suffered an electrical burn to the right hand and was hospitalized.

Abbott Electric Inc

An employee was moving a scissor lift through a doorway. The employee was pinned between the scissor lift and the doorframe, sustained a back injury, and was hospitalized.

Mintcrest Corp

An employee was standing on an A-frame ladder approximately 6 feet above the floor while he attached a suspended light fixture to the ceiling. The employee lost balance, and fell to the tiled floor below, sustaining blunt force trauma to his head.

Cupertino Electric, Inc.

An employee was inspecting the overhead area of a single-person lift and repositioning the lift through a double doorway. As they were transitioning through the doorway, they were caught between the doorframe and the vertical mast of the lift. The employee was hospitalized with injuries to the nose, left maxillary sinus, left orbital bone, and left jaw, with fractures at the maxillary sinus area.

Swedberg Electric, LLC

The injured employee was performing routine maintenance on a fan belt/pulley. The injured employee and another person were moving the pulley back and forth manually to find a bearing issue. The injured employee's left ring finger got caught between the belt and the pulley wheel, resulting in a soft tissue amputation.

United States Postal Service

An employee was working to deliver mail to an apartment building. She was waiting for a customer to move, to obtain clearance to the mailboxes. The door swung inward and closed on her right little finger. The top half of her finger was surgically amputated.

Foundation Steel, LLC

An employee fell from a step ladder while reaching for a tie-off point. He impacted the ground, and landed on his bolt bag which contained tools. The employee was hospitalized with fractured ribs, and a lacerated spleen and kidney.

GXO Logistics

On October 30, 2025, an employee was working to adjust a stackable metal shipping container. As the container dropped into place, it caught the employee's hands in an area between the upper and lower cross-members. The employee suffered a laceration to the left ring finger that required stitches, bruising to the right ring finger, and fractures to the right middle finger that necessitated medical amputation of the fingertip.

Abbott Electric Inc

An employee was moving a scissor lift through a doorway. The employee was pinned between the scissor lift and the doorframe, sustained a back injury, and was hospitalized.

American Electric Power Company

An employee was setting up communication equipment for a meeting. They were walking and tripped over a speaker on the ground. The employee sustained a leg injury.